Reviewing the Site Requirements
Reviewing the Site Requirements
Please review the site requirements before you install the RoamAbout R2.
Hardware Requirements
The physical specifications for the RoamAbout R2 are provided in
Table 1-1 RoamAbout R2 Physical Specifications (with security cover)
Parameter
Width
Depth
Length
Weight
Environmental Requirements
Ensure that the environmental requirements are within the ranges described in
Table 1-2 Environmental Specifications
Parameter
Operating Environment
Air flow
Altitude
Relative humidity
Shock
Temperature
Vibration
Nonoperating Environment
Altitude
Relative humidity
1-2 Preparing for Installation
Approximate Specification
173.4 mm (6.84 in.)
62.3 mm (2.45 in.)
200.8 mm (7.90 in.)
1.47 kg (3.25 lb)
Description
Convection cooled
-60 meters (-197 feet) below sea level to 4000 meters
(13,123 feet) above sea level
5% to 95% (non-condensing)
Amplitude 10G, shock spectrum
each axis
-5°C to 50°C (23°F to 122°F)
10 Hz to 150 Hz, 20 sweeps/axis @ 0.5G, and 4 Hz to
50 Hz up to 1G
-60 meters (-197 feet) below sea level to 4000 meters
(13,123 feet) above sea level
0 to 95% (non-condensing)
Table
1-1.
Table
1
/
sine, 6 shocks on
2
1-2.