8 - PARAMETERS

8.4 - Versions

No.
551
552
553
556

8.5 - Fault level

No.
Description
602
Air intake filter 1 fouled
606
Exhaust filter 1 fouled
609
Electric heater safety thermostat
615
rotary heat exchanger
620
Supply air temperature too low
621
Supply air temperature too high
622
Return temperature too low
623
Return temperature too high
624
Room temperature too low
625
Room temperature too high
628
supply air duct pressure too low
629
supply air duct pressure too high
632
Loss of communication with energy meter
635
Loss of communication with Th Tune
Loss of communication with the heat recovery
636
unit outlet sensor, intake side
640
room temperature sensor
642
energy meter
650
Coil 1 pump fault
651
Coil 2 pump fault
652
exhaust duct pressure too low
653
exhaust duct pressure too high
58
Description
AHU software version
AHU Bios version
AHU boot version
SO number
Setting
Enumeration
By default
0: Maintenance
0
1: Danger
0: Maintenance
0
1: Danger
0: Maintenance
0
1: Danger
0: Maintenance
0
1: Danger
0: Maintenance
0
1: Danger
0: Maintenance
0
1: Danger
0: Maintenance
0
1: Danger
0: Maintenance
0
1: Danger
0: Maintenance
0
1: Danger
0: Maintenance
0
1: Danger
0: Maintenance
0
1: Danger
0: Maintenance
0
1: Danger
0: Maintenance
0
1: Danger
0: Maintenance
0
1: Danger
0: Maintenance
0
1: Danger
0: Maintenance
0
1: Danger
0: Maintenance
0
1: Danger
0: Maintenance
0
1: Danger
0: Maintenance
0
1: Danger
0: Maintenance
0
1: Danger
0: Maintenance
0
1: Danger
Access level
1
1
1
3
Display conditions
P32 Electric heater = 1 on/off stage
or 2 on/off stages
or 1 gradual stage
or 1 gradual stage and 1 on/off stage
or
P31 Electric preheater = with
P36 Heat recovery unit = Gradual speed 
heat recovery unit
P146 Target temperature selection = return 
air
P146 Target temperature selection = return 
air
P146 Target temperature selection = room
P146 Target temperature selection = room
P104 Air intake ventilation control = Duct 
pressure
P104 Air intake ventilation control = Duct 
pressure
P44 Energy meter = With
P149 = with
P38 Temperature sensor upstream of heat
recovery unit = With
P149 = with
P44 Main unit energy meter = With
P92 Coil no. 1 pump = with
P93 Coil no. 2 pump = with
P105 Exhaust ventilation control = Duct 
pressure
P105 Exhaust ventilation control = Duct 
pressure
Access
level
2
2
3
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2