Fastener Jam - Senco Fusion F-15XP Operating Instructions Manual

Cordless finish nailers
Table of Contents

Advertisement

This tool is equipped with an indicator light at the ON/OFF/MODE switch. See page 14 for detailed
instructions.
Note:
When the tool is in the sequential mode, a fastener cannot be driven by pulling the trigger before
activating the work piece contact element.
If the workpiece contact is activated for more than 10 seconds, the workpiece contact must be
released to start over.
When the tool is in contact actuation mode, if the operator holds the trigger on for more than 3
seconds, the light will go out and the trigger must be released to start over.
Solid or Flashing Green Light
Indicates the tool is energized and ready to drive.
If light does not turn on, look to be sure that the trigger or work contact element are free to move and not in the activated
position.
Solid Red Light
Indicates the tool has detected an error.
Low battery. The battery will usually detect the condition first and turn the tool off. Recharge the battery or replace with
a freshly charged battery to continue. If the tool has detected this condition first, it is usually due to sustained extreme
use. Replace the battery with a fully charged battery.
The tool detected a timing issue. This can be caused by low charge pressure, an application requiring drive energy
above the tools capacity, a loose battery connection or broken components. Re-insert the battery or replace the battery
with a freshly charged battery. If this does not remedy the issue, refer to the troubleshooting guide or contact an autho-
rized service center.
Flashing Red Light
Indicates a fastener jam.
The tool detects a jam which is usually due to a deformed nail wedged in the driver path.
Remove the battery from tool, re-insert battery and turn on tool. If tool does not return to normal operation, go to next step.
REMOVE the BATTERY
Unload all remaining fasteners in magazine. Make sure that any loose fastener from strip is also removed.
Remove the magazine (F-15XP) or accress the jammed fastener via the open magazine (F-16XP, F-18XP).
Carefully remove the jammed fastener.
Reassemble the magazine.
Attach charged battery to tool.
Load nails into magazine.
Resume normal operation.
If the wedged fastener can't be removed, return to an authorized service center where the damaged
fastener can be removed. Remember that the Fusion tool contains pressurized air at all times even
when the battery is removed.
TOOL OPERATION
This tool is equipped with a multi-purpose light in the
mode switch. The mode sensor light will indicate that the
electronic controls are energized, which operating mode
has been selected, if a jam was detected and when the
battery requires a full recharge.
15