R
E
P
Section
Reporting Code
#
[349-350]
AC Line Trouble/Rest.
[349-350]
Main Bell Trouble/Rest.
[349-350]
Fire Trouble/Rest.
[349-350]
Auxiliary Power Trouble/Rest.
[349]
TLM Failure
[350]
TLM Restore
[349-350]
Gen System Supervisory
Trouble/Rest.
[349-350]
General System Trouble/Restore "Service Required"trouble occurs (view troubles using [*][2][3])/
[351]
Line 1 or 2 FTC Restoral
[351]
Event Buffer is 75% Full
[351]
DLS Lead In
[351]
DLS Lead Out
[351]
General Zone Trouble/Rest.
[351]
Delinquency
[352]
Periodic Test
[352]
System Test
[352]
LINKS Test
[353]
General Device Low Battery
Trouble/Rest.
†Program the "Fail to close" event code [(4)54] to report either closing or activity delinquency. Make sure your central station is aware of the application of this
Contact ID Zone Alarm/Restoral Event Codes
(as per ADEMCO):
Program any of these codes for zone alarms/restorals when
using the standard (non-automatic) Contact ID reporting format.
Medical Alarms
(1)AA Medical
(1)A1 Pendant Transmitter
(1)A2 Fail to Report In
Fire Alarms
(1)1A Fire Alarm
(1)11 Smoke
(1)12 Combustion
(1)13 Water Flow
(1)14 Heat
(1)15 Pull Station
(1)16 Duct
(1)17 Flame
(1)18 Near Alarm
Panic Alarms
(1)2A Panic
(1)21 Duress
(1)22 Silent
(1)23 Audible
Burglar Alarms
(1)3A Burglary
(1)31 Perimeter
(1)32 Interior
O
R
T
Code Sent When...
AC power to control panel is disconnected or interrupted/AC
power restored (Both codes follow AC Failure Comm. Delay.)
open circuit detected across bell terminals/bell circuit closed
a trouble occurs/restores on a fire zone
aux voltage supply trouble/restoral
telephone line monitoring trouble (sent via LINKS. Do not
program if LINKS not used)
Telephone line trouble restore
control panel loses/restores communications with module(s)
connected to the Keybus
troubles restored
control panel has restored communications to central station on
line 1or 2 (after FTC)
event buffer is almost full since last upload
downloading session start
downloading session complete
one or more zones have trouble/trouble restored
programmed amount of time (days or hours) for delinquency has
expired without zone activity or without system being armed
periodic sytem test transmission
[*][6] bell/communications test
LINKS test transmission
Wireless zones/pendants (WLS908);
handheld keypads (WLS910); wireless keys (WLS909) have low
battery/all low batteries restored
* A/R = alarms/restorals;T/R = tampers/restorals; O/C = openings/closings; MA/R = miscellaneous alarms/restorals; T = test transmissions
Table 2
(1)33 24 Hour
(1)34 Entry / Exit
(1)35 Day / Night
(1)36 Outdoor
(1)37 Tamper
(1)38 Near Alarm
General Alarms
(1)4A General Alarm
(1)43 Exp. module failure
(1)44 Sensor tamper
(1)45 Module Tamper
(1)4A Cross Zone Police Code
24 Hour Non-Burglary
(1)5A 24 Hour non-Burg
(1)51 Gas detected
(1)52 Refrigeration
(1)53 Loss of Heat
(1)54 Water Leakage
(1)55 Foil Break
(1)56 Day Trouble
(1)57 Low bottled Gas level
(1)58 High Temp
(1)59 Low Temp
(1)61 Loss of Air Flow
I
N
G
SIA Format Automatic Zone Alarm/Restoral Codes
Zone Definition
Delay, Instant, Interior, Delay
Stay/Away, Interior Stay/Away,
24Hr Burg.
Standard 24Hr Fire, Delayed 24Hr
Fire
24Hr Supervisory
24Hr Supervisory Buzzer
24Hr Sprinkler
24Hr Gas
24Hr Heat
24Hr Medical
24Hr Emergency (non-medical)
24Hr Waterflow
24Hr Freeze
24Hr Holdup
24Hr Panic
Latching 24Hr
44
C
O
Dialer
Contact
Direction*
ID Codes
MA/R
MA/R
MA/R
MA/R
MA/R
MA/R
MA/R
MA/R
MA/R
MA/R
MA/R
MA/R
MA/R
MA/R
T
T
T
MA/R
** UU = user number (user01-42); ZZ = zone number (01-08)
Table 3
* ZZ = zones 01-08
D
E
S
SIA Auto Rep
Codes**
(3) A1
AT-00/AR-00
(3) 21
UT-99/UJ-99
(3) 73
FT-00/FJ-00
(3) AA
YP-00/YQ-00
(3) 51
LT-00
(3) 51
LR-00
(3) 33
ET-00/ER-00
(3) 3A
YX-00/YZ-00
(3) 54
YK-00
(6) 23
JL-00
(4) 11
RB-00
(4) 12
RS-00
(3) 72
UT-00/UJ-00
(4) 54†
CD-00
(6) A2
RP-00
(6) A1
RX-00
(6) A3
TX-00
(3) 84
XT-00/XR-00
reporting code.
SIA Auto Rep
Codes*
Zone Alm/Rest.
BA-ZZ/BH-ZZ
FA-ZZ/FH-ZZ
US-ZZ/UR-ZZ
UA-ZZ/UH-ZZ
SA-ZZ/SH-ZZ
GA-ZZ/GH-ZZ
KA-ZZ/KH-ZZ
MA-ZZ/MH-ZZ
QA-ZZ/QH-ZZ
WA-ZZ/WH-ZZ
ZA-ZZ/ZH-ZZ
HA-ZZ/HH-ZZ
PA-ZZ/PH-ZZ
BA-ZZ/BH-ZZ