The panel will immediately go on line and begin downloading. If
the Call-Back option is enabled, the panel and the computer will
both hang up. The panel will then call the Downloading
Computer's Telephone Number and wait for the computer to
answer. Once the computer answers, downloading will begin.
If the User Enabled DLS Window option is ON, the user can
activate the downloading feature for a set period of time by
entering [ ] [6] [Master Code] [5].
If the Full 6-hour User Enabled DLS Window option is enabled,
when the user opens the DLS window with [ ][6][Master
code][5], the DLS window will remain open for six hours. The
DLS window will remain open after a successful hang-up from
a downloading call. If the One Time 1-hour User Enabled DLS
Window option is enabled, when the user opens the DLS
window with [ ][6][Master code][5], the DLS window will stay
open for one hour, and will close after a successful hang-up
from a downloading call.
After six hours, the panel will not answer incoming calls unless
the Answering Machine/Double Call option is enabled, or the
Number of Rings is programmed to be more than [0].
If the User Initiated Call-Up option is enabled, the user can
have the panel initiate a call to the downloading computer by
pressing [ ][6][Master Code][6].
The Download Access Code and Panel Identifier Code are for
security and proper identification. Both the panel and the computer
file should contain the same information programmed before
attempting to download.
The time to complete a successful download can be significantly
reduced with the use of the PC-LINK. This adaptor makes it
possible to perform on-site downloading. To Initiate Local
Downloading via the PC-LINK, enter [ ] [8] [Installer's Code]
[499] [Installer's Code] [499]. All keypads will be busy for the
duration of the PC-LINK connection. The status LEDs will display
the current system status on the keypad where the PC-LINK was
initiated. For more information on connecting the PC-LINK, refer
to your "PC-LINK Download Kit Instruction Sheet".
When a zone status upload is performed through
PC-LINK, the information uploaded may not be
accurate. For more information, refer to your DLS-
1 manual.
Downloading can also be performed through the LINKS 1000
cellular communicator if the telephone line is disconnected. If
using the LINKS1000 with Call Back, you need to program the
LINKS 1000 Preamble with the downloading telephone number
in order for the panel to call the computer correctly.
When uploading labels from LCD keypads, only
labels from the LCD keypad assigned to slot 8 will
be uploaded.
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
Answering Machine/Double Call ............... Section [401]: [1]
User Enable DLS Window .......................... Section [401]: [2]
Call-Back .................................................... Section [401]: [3]
User-initiated Call-up enabled/disabled ... Section [401]: [4]
One/Six Hour User-enabled DLS Window . Section [702]: [7]
Downloading Computer's Telephone Number . Section [402]
Downloading Access Code .............................. Section [403]
Panel Identification Code .................................. Section [404]
Answering Machine Double Call Timer ............ Section [405]
Number of Rings to Answer On ........................ Section [406]
LINKS 1000 Preamble (Downloading) .............. Section [490]
Initiate Local Downloading (PC-LINK) .............. Section [499]
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
R
A
M
D
E
S
C

5.11 PGM Output Options

Programmable outputs can be programmed by selecting one
of the output options listed below (exceptions noted).
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
Main Board PGM Outputs ................................. Section [009]
PC5208 PGM Outputs ....................................... Section [010]
PC5204 PGM Outputs ....................................... Section [011]
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
PGM outputs cannot be disabled in installer's
programming. To disable a PGM output, you must
remove all wiring from the output.
[01] Burglary and Fire Bell Output
The output will activate when the alarm output is active and will
deactivate when the alarm output is silenced. If the alarm output
is pulsing, the PGM output will pulse as well. This output will follow
the activation of the alarm output (pre-alert) for delayed fire zones.
[02] For Future Use
[03] Sensor Reset ([ ] [7] [2])
This output will normally be active (switched to
ground).
This option is used to reset power for latching smoke detectors.
The output will deactivate for five seconds when the [ ] [7] [2]
command is entered (see Section 3.4 "[ ] [7] Output Functions").
The keypad buzzer will not sound for the five second period.
Please refer to the Control Panel Wiring Diagram in this manual
for wiring instructions.
Only ONE of options [03] Sensor Reset and [20] [ ]
[7] [2] Command Output Option #2 may be pro-
grammed on the same system.
[04] For Future Use
[05] Armed Status
When the system is armed, the PGM output will activate at the
beginning of the exit delay. The output deactivates when the
system is disarmed.
[06] Ready To Arm
The PGM will be active as long as the system is ready to arm and
all non-force armable zones on the system are restored. Once
an access code is entered to arm the system and the exit delay
begins, the PGM output is deactivated.
[07] Keypad Buzzer Follower Mode
The PGM will activate when any of the following events occur
and will remain active for as long as the keypad buzzer is active:
• Door Chime
• Auto-Arm Prealert
• 24 Hour Supervisory Buzzer Zone
[08] Courtesy Pulse
Upon arming, the PGM output will activate for the duration of the
exit delay plus an additional two minutes. Upon entry, the PGM
output will activate for the duration of the entry delay plus an
additional two minutes. This output will also activate for two
minutes when disarming.
[09] System Trouble Output
The PGM output will activate when any of the selected trouble
conditions are present. It will deactivate when all the selected
trouble conditions are cleared.
The PGM attributes for this option, programmed in Sections
[141] to [142], differ from the standard selection of attributes.
21
R
I
P
T
• Entry Delay
• Audible Exit Delay
I
O
N
S