AMG AMG5514A9-DF-MP Instruction Manual

AMG AMG5514A9-DF-MP Instruction Manual

Revieve unit with one bi-directional data channel, one bidirectional alarm and one bi-directional audio channel for a singlemode fibre link

Advertisement

Quick Links

Revieve Unit with one Bi-directional Data Channel, one Bi-
directional Alarm and one Bi-directional Audio Channel for
122mm
between
slot
centres
The AMG5514A9-DF-MP is a standalone recieve unit designed to transmit & receive one Bi-
directional alarm, one Bi-directional audio channel and one Bi-directional data signal over two
Singlemode optical fibres.
The AMG5514A9-DF-MP is designed to be powered using an AMG2001 standalone power supply.
The AMG5514A9-DF-MP is designed to operate with an AMG5513A9-DF-MP / AMG5513A9R-DF
receive unit in a point to point configuration. The R suffix in the part no. indicates a rackmount version.
AMG Systems Ltd. reserves the right to make changes to this
document without notice. The information herein is believed to
be accurate. No responsibility is assumed by AMG for its use.
a Singlemode Fibre Link
172mm overall
155mm between mounting slot
centres (4mm slots)
AMG5514A9-DF-MP
Instruction Manual
Page 1 of 12
AMG5514A9-DF-MP Instruction Sheet
D17395-00.doc
132mm
overall

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AMG5514A9-DF-MP and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for AMG AMG5514A9-DF-MP

  • Page 1 155mm between mounting slot centres (4mm slots) The AMG5514A9-DF-MP is a standalone recieve unit designed to transmit & receive one Bi- directional alarm, one Bi-directional audio channel and one Bi-directional data signal over two Singlemode optical fibres. The AMG5514A9-DF-MP is designed to be powered using an AMG2001 standalone power supply.
  • Page 2: Table Of Contents

    Physical Information Dimensions ............................10 Mounting Details ..........................10 Safety Maintenance and Repair AMG Systems Ltd. reserves the right to make changes to this Page 2 of 12 AMG5514A9-DF-MP Instruction Sheet document without notice. The information herein is believed to D17395-00.doc...
  • Page 3: Introduction

    1 audio signal transmitted from the AMG5513A9-DF-MP. Optical Connection The AMG5514A9-DF-MP connections are illustrated in the following example which shows an AMG5514A9-DF-MP transmit unit together with an AMG5513A9-DF-MP standalone receive unit configured as a single channel point to point system.
  • Page 4: Connections

    Input impedance ........10kΩ / 600Ω Output impedance ....... 600Ω Frequency response ......10Hz to 20KHz AMG Systems Ltd. reserves the right to make changes to this Page 4 of 12 AMG5514A9-DF-MP Instruction Sheet document without notice. The information herein is believed to D17395-00.doc...
  • Page 5 *See appropriate section on how to remove the case for access to the data/audio switches. 1-2 – High Impedance 10kΩ 2-3 – Balanced 600Ω AMG Systems Ltd. reserves the right to make changes to this Page 5 of 12 AMG5514A9-DF-MP Instruction Sheet document without notice.
  • Page 6: Front Panel Indicators

    > 0dBm (overload at +6dBm) audio not present or < -40dBm This represents the audio signals being received from the optical fibre. AMG Systems Ltd. reserves the right to make changes to this Page 6 of 12 AMG5514A9-DF-MP Instruction Sheet document without notice.
  • Page 7: Data And Alarm Channel Configuration

    RS-485 bus high (+5 volts) and the other arm low (0 volts) using high value resistors within the third party equipment. In order to ensure that the AMG equipment detects a tri-state condition, then these resistors should have a value above 5kΩ. If the third party bias resistors are less the 750Ω...
  • Page 8: Data Interface Connections

    330R pull-up resistor to the internal +3V3 supply. The alarm output can receive an on/off signal from an AMG5514A9-DF-MP and is typically used to convey contact closure status. An alarm output uses a solid-state relay, with a maximum load current of 150mA at 125Vac/dc and Ron <...
  • Page 9: Audio Interface Connections

    OUT - OUT + OUT + IN + IN - AMG Systems Ltd. reserves the right to make changes to this Page 9 of 12 AMG5514A9-DF-MP Instruction Sheet document without notice. The information herein is believed to D17395-00.doc be accurate. No responsibility is assumed by AMG for its use.
  • Page 10: Physical Information

    Depth ........... 35mm Weight ..........600grams Mounting Details The AMG unit is supplied with a mounting plate which should be attached to a panel or wall using 4 off 4.0mm screws, see diagram on page 1 for dimensions. Safety AMG Optical Fibre Products use Class 1 laser systems in accordance with EN 60825-2:2000.
  • Page 11 This page is intentionally blank. AMG Systems Ltd. reserves the right to make changes to this Page 11 of 12 AMG5514A9-DF-MP Instruction Sheet document without notice. The information herein is believed to D17395-00.doc be accurate. No responsibility is assumed by AMG for its use.
  • Page 12 This page is intentionally blank. AMG Systems Ltd. reserves the right to make changes to this Page 12 of 12 AMG5514A9-DF-MP Instruction Sheet document without notice. The information herein is believed to D17395-00.doc be accurate. No responsibility is assumed by AMG for its use.

This manual is also suitable for:

Amg5513a9-df-mp

Table of Contents