Single Channel Video Receive Unit with one Bi-directional
Data Channel, one Bi-directional Alarm Channel and one
Bi-directional Audio Channel plus 1 Echelon FTT-10A data
signal for a Singlemode Fibre Link
The AMG5714A6B9-HP is a standalone one channel video receive unit designed to receive 1 video
signal and transmit & receive one data signal, one Bi-directional Alarm and one Bi-directional Audio
Channel plus 1 Echelon FTT-10A data signal over one Singlemode optical fibre.
The AMG5714A6B9-HP is designed to be powered using an AMG2001 standalone power supply.
The AMG5714A6B9-HP is designed to operate with an AMG5713A6B9-HP / AMG5713A6B9-HP-R
single channel video receive unit in a point to point configuration. The R suffix in the partno. indicates
a rackmount configuration.
AMG Systems Ltd. reserves the right to make changes to this
document without notice. The information herein is believed to
be accurate. No responsibility is assumed by AMG for its use.
AMG5714A6B9-HP
Instruction Manual
Page 1 of 12
AMG5714A6B9-HP Instruction Sheet
D22204-00.doc

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AMG5714A6B9-HP and is the answer not in the manual?

Questions and answers

Summary of Contents for AMG AMG5714A6B9-HP

  • Page 1 Bi-directional Audio Channel plus 1 Echelon FTT-10A data signal for a Singlemode Fibre Link The AMG5714A6B9-HP is a standalone one channel video receive unit designed to receive 1 video signal and transmit & receive one data signal, one Bi-directional Alarm and one Bi-directional Audio Channel plus 1 Echelon FTT-10A data signal over one Singlemode optical fibre.
  • Page 2: Table Of Contents

    Physical Information Dimensions ............................12 Mounting Details ..........................12 Safety Maintenance and Repair AMG Systems Ltd. reserves the right to make changes to this Page 2 of 12 AMG5714A6B9-HP Instruction Sheet document without notice. The information herein is believed to D22204-00.doc...
  • Page 3: Introduction

    AMG5713A6B9-HP. Optical Connection The AMG5714A6B9-HP connections are illustrated in the following example which shows an AMG5713A6B9-HP transmit unit together with an AMG5714A6B9-HP standalone receive unit configured as a single channel point to point system. AMG Systems Ltd. reserves the right to make changes to this...
  • Page 4: Connections

    Connector Partno......... Phoenix 1881354 Input level ..........0dBm Input overload level ......+6dBm AMG Systems Ltd. reserves the right to make changes to this Page 4 of 12 AMG5714A6B9-HP Instruction Sheet document without notice. The information herein is believed to D22204-00.doc...
  • Page 5 *See appropriate section on how to remove the case for access to the data/audio switches. 1-2 – High Impedance 10kΩ 2-3 – Balanced 600Ω AMG Systems Ltd. reserves the right to make changes to this Page 5 of 12 AMG5714A6B9-HP Instruction Sheet document without notice.
  • Page 6: Front Panel Indicators

    (-V) present on OUT+ OUT corresponds to the data signals being received from the optical fibre. Auxiliary Data LEDs Data type depends on AMG system: RS-232, RS-422, RS-485, 20mA,TTL, or FTT-10A Data Present IN ........Green Data channel present but not transmitting...
  • Page 7 > 0dBm (overload at +6dBm) audio not present or < -40dBm This represents the audio signals being received from the optical fibre. AMG Systems Ltd. reserves the right to make changes to this Page 7 of 12 AMG5714A6B9-HP Instruction Sheet document without notice.
  • Page 8: Echelon Ftt-10A Data Channel Configuration

    Echelon FTT-10A Data Channel Configuration The AMG5714A6B9-HP receive unit sends and receives Echelon FTT-10A data to/from an AMG5713A6B9-HP or rackmount equivalent AMG5713A6B9-HP-R transmit unit. The auxiliary data channel is provided by an X13038 Echelon Daughter Board, it provides one bi- directional Echelon FTT10A data channel.
  • Page 9: Data And Alarm Channel Configuration

    RS-485 bus high (+5 volts) and the other arm low (0 volts) using high value resistors within the third party equipment. In order to ensure that the AMG equipment detects a tri-state condition, then these resistors should have a value above 5kΩ. If the third party bias resistors are less the 750Ω...
  • Page 10: Data Interface Connections

    Note: (A) or (B) in brackets in the above table refers to RS-485 / RS-422 data specification. Alarm Channel Configuration The AMG5714A6B9-HP provides one bi-directional alarm output / contact closure input. The alarm input is typically connected to a contact closure switch. An ALARM IN+ input incorporates a 330R pull-up resistor to the internal +3V3 supply.
  • Page 11: Audio Channel Configuration

    OUT - OUT + OUT + IN + IN - AMG Systems Ltd. reserves the right to make changes to this Page 11 of 12 AMG5714A6B9-HP Instruction Sheet document without notice. The information herein is believed to D22204-00.doc be accurate. No responsibility is assumed by AMG for its use.
  • Page 12: Physical Information

    Weight ..........600grams Mounting Details The AMG unit is supplied with a clip-on mounting bracket which should be attached to a panel or wall using 2 off 4.0mm screws, see diagram on page 1 for dimensions. The unit is clipped into the mounting bracket, and is then held firmly in position.