Data receive unit with 2 bi-directional data channels, 6 bidirectional audio channels, 2 echelon ftt-10a data channels and 8 bi directional alarms plus ethernet for a multimode fibre link
Receive unit with two bi-directional data channels, two bidirectional audio channels, eight bi-directional alarms plus ethernet for a multimode dual fibre link (12 pages)
Data receive unit with 2 bi-directional data channels, 6 bidirectional audio channels, 2 echelon ftt-10a data channels and 8 bi-directional alarms plus ethernet for a dual multimode fibre link (12 pages)
Single channel video receive unit with one bi-directional data channel, one bi directional alarm and one bidirectional audio channel for a singlemode fibre link (12 pages)
Single channel video receive unit with one bi-directional data channel and six uni-directional alarms plus dual redundant operation for a singlemode fibre link (8 pages)
Single channel video receive unit with one bi-directional data channel, one bi-directional alarm channel and one bi-directional audio channel plus 1 echelon ftt-10a data signal for a singlemode fibre linksingle channel video receive unit with one bi-direc (12 pages)
Single channel video receive unit with two bi-directional data channels, 2 bi-directional audio channels, eight bi-directional alarms plus ethernet for a singlemode fibre link (12 pages)
Single channel video receive unit with two bi-directional data channels, 2 bi-directional audio channels, eight bi-directional alarms plus ethernet for a singlemode fibre link (12 pages)
Data receive unit with 2 bi-directional data channels, 16 bi-directional audio channels and 8 bi-directional alarms plus ethernet for a singlemode fibre link (12 pages)
Single channel video receive unit with one bi-directional data channel and two uni-directional alarms for a singlemode fibre link (8 pages)
Summary of Contents for AMG AMG5804A966G
Page 1
Channels and 8 Bi-directional Alarms plus Ethernet for a Multimode Fibre Link The AMG5804A966G is a rackmount data receive unit designed to transmit and receive 2 data channels, 6 audio channels, 2 Echelon FTT-10A data channels and 8 bi-directional alarms over one Multimode optical fibre.
Physical Information Dimensions ............................12 Mounting Details ..........................12 Safety Maintenance and Repair AMG Systems Ltd. reserves the right to make changes to this Page 2 of 12 AMG5804A966G Instruction Sheet document without notice. The information herein is believed to D22145-00.doc...
Ethernet connectivity is also provided between the two units. Optical Connection The AMG5804A966G connections are illustrated in the following example which shows an AMG5803A966G data transmit unit together with an AMG5804A966G rackmount data receive unit configured as a point to point system.
Frequency response ......10Hz to 20KHz Echelon FTT-10A Data Channel Connection No. of Echelon FTT-10A Data Channels AMG Systems Ltd. reserves the right to make changes to this Page 4 of 12 AMG5804A966G Instruction Sheet document without notice. The information herein is believed to D22145-00.doc...
Ethernet Data Connector ....RJ45 Interface..........Auto MDI/MDIX 100BASE-TX Ethernet Data Rate......Maximum 100Mb/s full duplex AMG Systems Ltd. reserves the right to make changes to this Page 5 of 12 AMG5804A966G Instruction Sheet document without notice. The information herein is believed to D22145-00.doc...
> 0dBm (overload at +6dBm) audio not present or < -40dBm This represents the audio signals being received from the optical fibre. AMG Systems Ltd. reserves the right to make changes to this Page 6 of 12 AMG5804A966G Instruction Sheet document without notice.
Alarm ON / Contacts closed. Alarm OFF / Contacts open. Echelon FTT-10A Data LEDs Data type depends on AMG system: RS-232, RS-422, RS-485, 20mA,TTL, or FTT-10A Data Present IN ........Green Data channel present but not transmitting Data channel transmitting Data channel not present or no connection IN corresponds to the data signals being transmitted onto the optical fibre.
RS-485 bus high (+5 volts) and the other arm low (0 volts) using high value resistors within the third party equipment. In order to ensure that the AMG equipment detects a tri-state condition, then these resistors should have a value above 5kΩ. If the third party bias resistors are less the 750Ω...
RS-232 (no termination), RS-422 (120Ω) or RS-485 (120Ω). Alarm Channel Configuration The AMG5804A966G provides 8 bi-directional contact closure inputs / alarm outputs. Each ALARM IN input is via an internal 10kΩ series resistor with a 47kΩ pull-up resistor to the internal +3V3 supply.
The GND connection associated with any Data signal signal should be connected to one of the GND pins available on the 37way D-type connector. These GND inputs are common to all audio / data channels. AMG Systems Ltd. reserves the right to make changes to this Page 10 of 12 AMG5804A966G Instruction Sheet document without notice.
Notes: Bank A : Channels 1-6 are Audio and Channels 7 & 8 are FTT-10A Data. Bank B : Not Fitted AMG Systems Ltd. reserves the right to make changes to this Page 11 of 12 AMG5804A966G Instruction Sheet document without notice. The information herein is believed to D22145-00.doc...
There are no user serviceable parts within AMG products. See unit data sheet for full specification. In case of problem or failure, please call your local support centre or contact: AMG Systems Ltd. at 3 The Omega Centre, Stratton Business Park, Biggleswade, Beds., SG18 8QB, UK.