ARTRAY ARTCAM-990SWIR-TEC-CL Setting Manual

Camera link
Hide thumbs Also See for ARTCAM-990SWIR-TEC-CL:

Advertisement

Quick Links

Camera Link Setting Manual
990SWIR-TEC-CL
ARTCAM-990SWIR-TEC-CL
Camera Link Setting Manual
rev.1.07
Rev.1.07
© 2004 – 2021 ARTRAY Co., Ltd
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ARTCAM-990SWIR-TEC-CL and is the answer not in the manual?

Questions and answers

Summary of Contents for ARTRAY ARTCAM-990SWIR-TEC-CL

  • Page 1 Camera Link Setting Manual 990SWIR-TEC-CL ARTCAM-990SWIR-TEC-CL Camera Link Setting Manual rev.1.07 Rev.1.07 © 2004 – 2021 ARTRAY Co., Ltd...
  • Page 2: Table Of Contents

    Capture mode ........................11 Settings ............................11 6.1. Preparation ..........................11 6.2. Connect to Camera ........................12 6.3. Example of Serial Communication Software Settings .............. 13 6.4. Example of Viewer Software Settings ..................15 Rev.1.07 © 2004 – 2021 ARTRAY Co., Ltd...
  • Page 3: Introduction

    Table 2-3: Tested Framegrabbers + Software Manufacturer Product name + software NI PCIe-1433 + NI MAX AVAL APX-3318 + AIPTool Xcelera-CL PX4 Full + CamExpert Dalsa EPIX PIXCIEB1 + XCAP ※ Tested CameraLink cable length: 2m Rev.1.07 © 2004 – 2021 ARTRAY Co., Ltd...
  • Page 4: Camera Link Format

    4. Connector Pin Assignment The connector pin assignment is as follows: Table 4-1: Connector Pin Assignment Pin No. Signal Name Pin No. Signal Name XCK- XCK+ CC0- CC0+ CC1+ CC1- CC2- CC2+ CC3+ CC3- Rev.1.07 © 2004 – 2021 ARTRAY Co., Ltd...
  • Page 5: Communication Specifications

    (e.g. BackSpace) before line any none- feed code, the response must be NG. half-width character before If you want to cancel the command, type a none- line feed code, the response will be NG. Rev.1.07 © 2004 – 2021 ARTRAY Co., Ltd...
  • Page 6: List Of Commands

    Mirror Horizontal mirror enable/disable - Show camera name Camera Information - Show firmware version Peltier ON - Peltier Control Peltier OFF - - Sets preview mode Capture mode Sets trigger mode - Rev.1.07 © 2004 – 2021 ARTRAY Co., Ltd...
  • Page 7: Commands Details

    5: Value of shutter speed 6: Line feed code Response Normal: OK⏎ Abnormal: NG⏎ Note Sets the shutter speed ※To calculate the shutter speed, please refer to the instruction of the camera. Rev.1.07 © 2004 – 2021 ARTRAY Co., Ltd...
  • Page 8: Gain

    3: -vf = Option: FPGA temperature readout 4: Line feed code Response Normal: temperature ⏎ Abnormal: NG⏎ Note To show the estimated temperature of camera FPGA. The temperature shown here is merely a reference. Rev.1.07 © 2004 – 2021 ARTRAY Co., Ltd...
  • Page 9: Mirror

    Format 〼 ⏎ Details 1: n = Camera information 2: Delimiter 3: -c = Option: Camera name 4: Line feed code Response Normal: ARTCAM-990SWIR-TEC-CL (example)⏎ Abnormal: NG⏎ Note To show camera name. Rev.1.07 © 2004 – 2021 ARTRAY Co., Ltd...
  • Page 10: Peltier

    Table 5-14: Peltier OFF Format 〼 ⏎ Details 1: p = Peltier 2: Delimiter 3: -n = Peltier OFF 4: Line feed code Response Normal: OK⏎ Abnormal: NG⏎ Note To disable peltier Rev.1.07 © 2004 – 2021 ARTRAY Co., Ltd...
  • Page 11: Capture Mode

    If you use our recommendations listed in table 2-2, the device names should be recognized as follows: Table 6-1: Devices Recognized Device PIXCI®EB1 PCI Express Camera Link Video Capture Board for Win XP/Vista/7/8/10-64bit PIXCI® Camera Link Serial Port (COM3※ : Will be differ depending on systems. ※ Rev.1.07 © 2004 – 2021 ARTRAY Co., Ltd...
  • Page 12: Connect To Camera

    Please connect camera to the Camera Link frame grabber board with Camera Link cable. Before connect AC adapter to the camera, please start up the serial communication software. Command will be sent from the camera once it is connected to the power. Rev.1.07 © 2004 – 2021 ARTRAY Co., Ltd...
  • Page 13: Example Of Serial Communication Software Settings

    Please click “Setup” on menu bar, then choose “Serial Port” for communication method settings. Please refer to table 5-1 Communication Method for details of the settings. Figure 6-4: To Set up Serial Port on Tera Term Rev.1.07 © 2004 – 2021 ARTRAY Co., Ltd...
  • Page 14 “OK” on the dialog box. Then you can send command to control camera. Please note that camera will start up only when you send out the command. Figure 6-6: Initialization Rev.1.07 © 2004 – 2021 ARTRAY Co., Ltd...
  • Page 15: Example Of Viewer Software Settings

    Figure 6-8: Welcome message Please click “PIXCI®” from XCAP menu, then choose “PIXCI®Open/Close” to open the dialog box. Please click “Open” to start the camera. Figure 6-9: To Open Camera Rev.1.07 © 2004 – 2021 ARTRAY Co., Ltd...
  • Page 16 Please refer to table 3-1 to confirm the Camera Link format. Figure 6-10: Configure Settings Second, please set the resolution. Please refer to table 3-2 to confirm the resolution of each model. Figure 6-11: Resolution Settings Rev.1.07 © 2004 – 2021 ARTRAY Co., Ltd...
  • Page 17 The settings are finished now. The image will be displayed either by clicking “Live” in “Capture” on the sub-window, or simply by clicking “Live Icon” on the left side of the sub-window. Figure 6-13: Live Icon Rev.1.07 © 2004 – 2021 ARTRAY Co., Ltd...

Table of Contents