8 Troubleshooting

8.1 Introduction & Precautions
This section provides a set of procedures for 
identifying and correcting problems with the 8500 
series amplifier. Rather than providing an exhaus-
tive and detailed list of troubleshooting specifica-
tions, this section aims to provide a set of short-
cuts intended to get an inoperative amplifier back 
in service as quickly as possible.
The procedures outlined in this section are direct-
ed toward an experienced electronic technician; 
it assumes that the technician has knowledge of 
typical electronic repair and test procedures.
Please be aware that the 8500 sesries will un-
dergo frequent engineering updates. As a result, 
modules and electronic assemblies may not be
interchangeable between units. Particularly, the 
circuit boards undergo periodic engineering modifi-
cations that may make interchangeability between 
units impossible.
ELECTRIC SHOCK HAZARD.
Follow these safety precautions before
opening the amplifier's back access
door:
• Disconnect the AC power supply.
• Wait at least 3-5 minutes after
disconnecting AC power before
opening the access door.
• Wear safety goggles.
• Contact AE Techron Technical
Support for any questions or
concerns.

8.2 Visual Inspection

Before attempting to troubleshoot the amplifier 
while it is operating, please take time to complete 
a visual inspection of the internal components of 
the amplifier.
1. To perform a Visual Inspection, first turn the 
Power switch to the Off (O) position.
2. Disconnect the AC mains from the amplifier.
24
WARNING
Information subject to change
8508 OPERATOR'S MANUAL – SECTION 8
3. Wait three to five minutes for the Power Supply 
capacitors to discharge.
4. Open the back acess door and check the fol-
lowing: 
Check to make sure the breaker switch on
all amplifier modules is in the ON position.
  I nspect the modules for loose or discon-
nected wires or connectors.
Inspect the bus bars connecting the ampli-
fier module's outputs for any signs of char-
ring or melting.
Inspect the entire lengths of wires and 
cables for breaks or other physical damage.
5. If there is any physical damage to the amplifier, 
please return it to AE Techron for repair.

8.3 No Signal

Missing Output signal may be caused by one of 
the following:
1. The Control Configuration DIP switch (#7) on the 
Master amplifier module is set to the Follower 
(down) position. This DIP switch should be set 
to the Master (up) position. See the Advanced
Configuration section in this manual for more
information.
2. A signal source is not connected to either in-
puts on the amplifier. See the Amplifier Setup
section in this manual for more information.

8.4 No LEDs Illuminated

If none of the LEDs on the Display Panel are il-
luminated, check the following:
1. The AC mains are not connected or not on
(see the Amplifier Setup section for more
information). 

8.5 Over/Under Line LED Lit

The amplifier will protect itself from AC mains volt-
age that is 10% above or below the voltage indi-
cated on the back panel. If the AC mains voltage is 
more than 10% outside the range of the operating 
voltage, increase or reduce the AC mains voltage 
to the proper level. When the line voltage condition 
is corrected, the amplifier will automatically return 
to Run mode. If the amplifier does not reset, the 
96-8005549_3-18-21