Installation - Windster WS-96TB30SS User Manual

Hide thumbs Also See for WS-96TB30SS:
Table of Contents

Advertisement

8

INSTALLATION

1. WALL MOUNT INSTALLATION
a.
Make sure all preparation steps are completed.
b.
Determine your ceiling height to see if you need an extension.
i. Hood unit height = 2" (30" model only)
ii. Hood unit height = 2" (36" model only)
iii. Duct cover height = 16-5/8" (lower) + 19-3/4" (upper)
iv. Minimum height (Standard duct cover only) = 19-3/4"
v. Maximum height (Standard duct cover only) = 35-1/2"
vi. (OPTIONAL) Extension DC Minimum height = 39-3/4"
vii. Maximum height (duct cover with extension only) = 55-1/2"
c.
Determine the location you want to install the range hood. (Fig. 2a)
d.
Prepare back wall frame with cross wood support.
e.
Mount the unit onto wall with mounting screws (not included)
f.
Adjust the duct cover mounting bracket to your desired height.
g.
Use a spirit level to ensure the balance of the hood is true.
h.
(OPTIONAL) Use the conversion collar for 7" ducting.
i.
Connect a 6" or 7" ducting to the collar of the hood.
j.
Connect the exhaust piping to the outlet of the unit. (Fig. 2b)
k.
Finish off by sealing the connection point with aluminum tape.
l.
Slide the duct cover into the unit and adjust its height. (Fig. 2c)
m. Secure it with the (6) duct cover screws provided. (Fig. 2d)
2. EXTENSION DUCT COVER INSTALLATION
EXTENSION MAY REQUIRE MODIFICATION
Windster Hood will not be responsible for any modification done.
a.
Replace the original upper duct cover piece with the extension.
b.
Determine the desired height (up to 10' ceiling) to mount the duct cover.
c.
REPEAT STEP F – M of Section 1 WALL MOUNT INSTALLATION
section.
INSTALLATION
INSTALLATION
 
3. COLD WEATHER INSTALLATION (OPTIONAL)
a.
Check with your local building codes to see if a CFM reducer is an
acceptable alternative to make-up air.
b.
Remove the WS-96TBCFMR (CFM Reducer) and inspect for any sign of
defect or damage. (ie. Cracks, broken flips)
c.
AFTER COMPLETING Step A – G of Section 1 WALL MOUNT
INSTALLATION.
d.
Place the CFM reducer onto the outlet of the unit and seal the connection
point with aluminum tape. (Be sure it is secure with no opening or gaps)
e.
Connect a 6" or 7" ducting to the collar of the hood.
f.
Connect the exhaust piping to the outlet of the unit. (Fig. 2b)
g.
Finish off by sealing the connection point with aluminum tape.
h.
Slide the duct cover into the unit and adjust its height. (Fig. 2c)
i.
Secure it with the (6) duct cover screws provided. (Fig. 2d)
4. DUCTLESS INSTALLATION
a.
AFTER COMPLETING Step A – G of Section 1 WALL MOUNT
INSTALLATION.
b.
Remove the WS-96TBDK (ductless kit) and inspect for any sign of defect
or damage. (ie. dents, broken inlet)
c.
Mount the ductless kit at the top of the duct using the screws provided.
d.
Make sure the duct cover vent opening aligns with the air diverter. (Fig.
2e)
e.
Connect a 6" or 7" ducting to the collar of the hood.
f.
Connect the exhaust pipe to the outlet of the unit. (Fig. 2b)
g.
Connect the exhaust pipe to the air diverter collar. (Fig. 2f)
h.
REPEAT STEP K – M of Section 1 WALL MOUNT INSTALLATION.
Installation diagram available on next page
9
 