Heater Specifications - L.B. White AB230 Owner's Manual And Instructions

Table of Contents

Advertisement

Heater Specifications

SPECIFICATIONS
Maximum Input
Ventilation Air Required
to Support Combustion
Inlet Gas Supply
Pressure Acceptable
at the Inlet of the
Heater for Purpose
of Input Adjustment
Burner Manifold Pressure
Fuel Consumption
MAX.
Per Hour
Motor Characteristics
Electrical Supply
(Volts/Hz/Phase)
Amp Draw
Dimensions
L x W x H
Minimum Safe
Distances From
Nearest
Combustible
Materials
4
MAX.
MIN.
STARTING
CONTINUOUS
OPERATION
TOP
SIDES
BACK
BLOWER
OUTLET
GAS
SUPPLY
L.P.
Gas
67.4 KW (242.42 MJ/h)
1,630 Cubic Meters per Hour
2.75 KPa
2.50 KPa
4.83 Kilograms per Hour
Ball Bearing, 187 Watts
240/50/1
78 CM x 46 CM x 72 CM
1.83 Meters
Reference AS1596 and AS5601 Gas Installations
Model
AB230
Natural
Gas
3.36 KPa
1.13 KPa
0.75 KPa
6.57 Cubic Meters per Hour
950 RPM
4.5
1.2
.3 Meters
.3 Meters
.3 Meters

Advertisement

Table of Contents
loading

Table of Contents