Warning Codes

In the event of a warning, the inverter display will flash. The last warning to occur is stored in parameter P931.
Warning
Cause
002
Current limit active
003
Voltage slip active
004
Slip limit exceeded.
005
Inverter overtemperature
(heatsink)
006
Motor over-temperature
010
Use power supply- current limit
018
Auto re-start after fault (P018)
is pending
075
Braking resistor-hot

System Parameters

Note: In the following parameter table:
l
Indicates parameters that can be changed during operation.
¶¶¶
Indicates that the value of this factory setting depends on the rating of the inverter.
If parameters are changed accidentally, all parameters can be reset to their default values by setting parameter P944 to 1 and
then pressing P.
Parameter Function
P001
Operating dis[lay
P001 l
Dis[lay mode
P002 l
Ramp up time (seconds)
P003 l
Ramp down time (seconds)
l
P004
Smoothing (seconds)
l
P005
Digital frequency setpoint (Hz)
P006
Frequency setpoint source selection
P007
Keypad control
l
P009
Parameter protection setting
P011
Frequency setpoint memory
l
P012
Minimum motor frequency (Hz)
l
P013
Maximum motor frequency (Hz)
l
P014
Skip frequency 1 (Hz)
l
P015
Automatic restart after mains failure
l
P016
Start on the fly
l
P017
Smoothing type
l
P018
Automatic restart after fault
l
P019
Skip frequency bandwidth (Hz)
P020
Flying start ramp time (seconds)
l
P021
Minimum analogue frequency (Hz)
l
P022
Maximum analogue frequency (Hz)
P051
Selection control function (DIN1 - terminal 5) fixed
frequency 3 or binary fixed frequency bit 0
P052
Selection control function (DIN2 - terminal 6) fixed
frequency 2 or binary fixed frequency bit 1
Corrective action
Check whether the motor power corresponds to the inverter power.
Check that the cable length limits have not been exceeded.
Check motor cable and motor for short-circuits and earth faults.
Check whether the motor parameters (P080-P085) correspond with the motor
being used.
Check the stator resistance (P089).
Increase the ramp start up time (P002).
Reduce the boost set in P078 and P079.
Check whether the motor is obstructed or overloaded.
Check that the ambient temperature is not too high.
Check that the air inlet and outlet are not obstructed.
Check that the inters integral fan is working.
Check if motor is overloaded.
Check that P087 has not been set to 1 without a PTC being connected.
WARNING: The inverter may start at any time.
9
Default
-
0
10.00
25.00
0.0
50.00
1
0
0
0
0.00
50.00
0.00
0
0
1
0
2.00
25.0
0.00
50.00
1
2
Your setting