Download Print this page

netvox R313W User Manual page 7

Wireless water leak sensor

Advertisement

(2)Read R313W device parameters:
Downlink: 0206000000000000000000
Device returns:
8206003C003C0100000000(Current configuration)
Example#1 based on MinTime = 1 Hour, MaxTime= 1 Hour, Reportable Change i.e. BatteryVoltageChange=0.1V
Max Time
S
leeping (Min Time)
1H
Wakes up and
collects data
REPORTS 2.8V
Note:
MaxTime=MinTime. Data will only be report according to MaxTime (MinTime) duration regardless BatteryVoltageChange
value.
Example#2 based on MinTime = 15 Minutes, MaxTime= 1 Hour, Reportable Change i.e. BatteryVoltageChange= 0.1V.
Sleeping (MinTime)
th
0H
15
M
Wakes up and
Wakes up and
collects data
collects data
2.8V
REPORT 2.8V
Does not report
2H
Wakes up and
collects data
REPORTS 2.8V
MaxTime
sleeping
sleeping
th
30
M
45
Wakes up and
Wakes up and
collects data
collects data
2.8V
Does not report
Does not report
Max Time
S
leeping (Min Time)
sleeping
th
M
1H
Wakes up and
collects data
REPORTS 2.8V
2.8V
6
3H
Wake up and
collects data
REPORTS 2.8V
2H

Advertisement

loading