Download Print this page

netvox R311CB User Manual

Wireless window sensor with glass break detector
Hide thumbs Also See for R311CB:

Advertisement

Quick Links

Model:R311CB
Wireless Window Sensor with Glass Break Detector
Wireless Window Sensor
with Glass Break Detector
R311CB
User Manual
Copyright©Netvox Technology Co., Ltd.
This document contains proprietary technical information which is the property of NETVOX Technology. It shall be maintained
in strict confidence and shall not be disclosed to other parties, in whole or in part, without written permission of NETVOX
Technology. The specifications are subject to change without prior notice.

Advertisement

loading
Need help?

Need help?

Do you have a question about the R311CB and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for netvox R311CB

  • Page 1 This document contains proprietary technical information which is the property of NETVOX Technology. It shall be maintained in strict confidence and shall not be disclosed to other parties, in whole or in part, without written permission of NETVOX Technology. The specifications are subject to change without prior notice.
  • Page 2: Table Of Contents

    Table of Content 1. Introduction ......................... 2 2. Appearance ......................... 3 3. Main Features ......................3 4.Set up Instruction ......................4 5. Data Report ......................... 5 5.1 Example of ConfigureCmd ................. 6 6. Installation ........................9 7. Important Maintenance Instruction ................10...
  • Page 3: Introduction

    When the window or door is opened, R311CB will send an alarm message to the gateway. When the door or window is closed, it will send a message that the state is normal. When the glass is broken, R311CB will send an alarm message to the gateway, and then the data which is sent after breakage is based on the current state.
  • Page 4: Appearance

     Applicable to the third-party platforms: Actility/ ThingPark/ TTN/ MyDevices/ Cayenne Note: Battery life is determined by sensor reporting frequency and other variables. Please refer to web: http://www.netvox.com.tw/electric/electric_calc.html In this website, users can find battery lifetime for various models at different configurations.
  • Page 5: Set Up Instruction

    4.Set up Instruction On/Off Insert batteries. (users may need a flat blade screwdriver to open); Power on Insert two sections of 3V CR2450 button batteries and close the battery cover.) Turn on Press any function key till green and red indicator flashes once. Press simultaneously and hold two function keys for 5 seconds, and then the green indicator will Turn off flash continuously.
  • Page 6: Data Report

    1. The cycle of the device sending the data report is according to the default. 2. The interval between two reports must be the MinTime. The device reported data parsing please refer to Netvox LoraWAN Application Command document and Netvox Lora Command Resolver http://loraresolver.netvoxcloud.com:8888/page/index...
  • Page 7: Example Of Configurecmd

    0x82 ReportRsp (2bytes Unit:s) (2bytes Unit:s) (1byte Unit:0.1v) (4Bytes, Fixed 0x00) (1) Configure R311CB device parameter MinTime = 1min, MaxTime = 1min, BatteryChange = 0.1v Downlink: 0156003C003C0100000000 Device return: 8156000000000000000000 (configuration success) 8156010000000000000000 (configuration failure) (2) Read R311CB device parameter Downlink:...
  • Page 8 (3) Configure the device to resend data within 5s after sending the packet Downlink: 1FFF050000000000000000 Device return: 9FFF000000000000000000 (configuration success) 9FFF010000000000000000 (configuration failure) (4) Read R311CB device parameter Downlink: 1EFF000000000000000000 Device return: 9EFF050000000000000000 (device current parameter) Example#1 based on MinTime = 1 Hour, MaxTime= 1 Hour, Reportable Change i.e. BatteryVoltageChange=0.1V...
  • Page 9 Example#3 based on MinTime = 15 Minutes, MaxTime= 1 Hour, Reportable Change i.e. BatteryVoltageChange= 0.1V. MaxTime Wakes up and collects Users push the button, data REPORTS 2.7V. 2.7V |2.7-2.8|=0.1 Wakes up and Recalculate MaxTime. REPORTS 2.7V collects data 2.7V sleeping sleeping Does not report 1H 10...
  • Page 10: Installation

    6. Installation 1. Remove the 3M release paper on the back of the device and 2. If R311CB with the glass sensor detects that the window is attach the device to the smooth wall (please do not stick it to opened (the magnet is separated from the main body) or the rough wall to avoid falling off after a longtime usage).
  • Page 11: Important Maintenance Instruction

    7. Important Maintenance Instruction The device is a product with superior design and craftsmanship and should be used with care. The following suggestions will help you use the warranty service effectively. • Keep the equipment dry. Rain, moisture and various liquids or water may contain minerals that can corrode electronic circuits.