netvox R313WA User Manual

Wireless 2-gang seat occupancy sensor
Hide thumbs Also See for R313WA:

Advertisement

Quick Links

Wireless 2-Gang Seat Occupancy Sensor
Wireless Seat Occupy Sensor
Copyright©Netvox Technology Co., Ltd.
This document contains proprietary technical information which is the property of NETVOX Technology and is issued
in strict confidential and shall not be disclosed to others parties in whole or in parts without written permission of
NETVOX Technology.
The specifications are subjected to change without prior notice.
R313WA
User Manual
Model: R313WA

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the R313WA and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for netvox R313WA

  • Page 1 Copyright©Netvox Technology Co., Ltd. This document contains proprietary technical information which is the property of NETVOX Technology and is issued in strict confidential and shall not be disclosed to others parties in whole or in parts without written permission of NETVOX Technology.
  • Page 2: Table Of Contents

    Table of Content 1. Introduction ..............2 2. Appearance ............... 3 3. Main Features ..............3 4. Set up Instruction ............. 4 5. Data Report ..............5 5.1 Example of ReportDataCmd ........6 5.2 Example of ConfigureCmd ........7 5.3 Example of Resendtime ..........8 5.4 Example for MinTime/MaxTime logic ......
  • Page 3: Introduction

    1. Introduction R313WA is a Class A wireless 2-gang seat occupancy device based on standard LoRaWAN protocol. The R313WA will report to the gateway whenever one of the 2-gang seat occupancy sensor detects external pressure. It will also report to the gateway when the external pressure is gone.
  • Page 4: Appearance

    2. Appearance Seat Sensor Indicator External Antenna Function Key 3. Main Features  Compatible with LoRaWAN  2 sections of 3V CR2450 button battery power supply  Detectable voltage and seat occupancy status  Simple operation and setting  Protection level IP30 ...
  • Page 5: Set Up Instruction

    4. Set up Instruction On/Off Insert batteries. Power on Note: Insert two sections of 3V CR2450 button batteries and close the battery cover. Turn on Press any function key till green and red indicator flashes once. Press and hold both function keys for 5 seconds till green indicator flashes for 20 Turn off (Restore to factory setting) times.
  • Page 6: Data Report

    DetectionTime: 0x0078 (120s) // Value must be greater than DetectionTime≧DisableTime Pressure Detecting: When the R313WA detects changes in pressure, it will report the status. When the seat is occupied, the status is 1. When the seat is unoccupied, the status is 0.
  • Page 7: Example Of Reportdatacmd

    Version– 1 byte –0x01——the Version of NetvoxLoRaWAN Application Command Version DeviceType– 1 byte – Device Type of Device The devicetype is listed in Netvox LoRaWAN Application Devicetype doc ReportType – 1 byte –the presentation of the NetvoxPayLoadData,according the devicetype NetvoxPayLoadData– Fixed bytes (Fixed =8bytes) Tips 1.
  • Page 8: Example Of Configurecmd

    MinTime MaxTime 0x01 (1byte DisableTime DectionTime (2bytes Unit:s) (2bytes Unit:s) Unit:0.1v) (2bytes Unit:s) (2bytes Unit:s) ConfigReport Status Reserved 0x81 (0x00_success) (8Bytes,Fixed 0x00) R313WA 0x5A ReadConfig Reserved 0x02 ReportReq (9Bytes,Fixed 0x00) BatteryChange Sensor Sensor ReadConfig MinTime MaxTime 0x82 (1byte DisableTime DectionTime...
  • Page 9: Example Of Resendtime

    5.3 Example of Resendtime FPort:0x07 Resend the occupancy status of the seat sensor. Device Description Device NetvoxPayLoadData Type SetLastMessage Resendtime Reserved 0x1F ResendtimeReq Suitable (1Byte,Unit:1s) (8Bytes,Fixed 0x00) SetLastMessage for use Status Reserved 0x9F ResendtimeRsp with (0x00_success) (8Bytes,Fixed 0x00) 0xFF GetLastMessage contact Reserved 0x1E...
  • Page 10: Example For Mintime/Maxtime Logic

    5.4 Example for MinTime/MaxTime logic Example#1 based on MinTime = 1 Hour, MaxTime= 1 Hour, Reportable Change i.e. BatteryVoltageChange=0.1V MaxTime MaxTime sleeping (MinTime) sleeping (MinTime) Wakes up and collect data Wakes up and collect data Wake up and collect data REPORTS 2.8V REPORTS 2.7V REPORTS 2.5V...
  • Page 11: Seat Occupancy Delay Configuration

    DetectionTime is the detecting period. (Please find further info regarding DisableTime and DetectionTime below.) (1) When R313WA detects pressure caused by the occupancy of the seat, it will report 1 (indicating the seat is taken) and other status (battery for example).
  • Page 12 While DetectionTime is 60 secs and DisableTime is 30 secs, pressure is detected during 25 sec. R313WA will restart pressure detect procedure (DetectionTime). No pressure is detected during next DetectionTime and R313WA therefore report un-pressure Triggered DetectionTime = 60 secs...
  • Page 13: Installation

    Note: 4. When no pressure is detected during DisableTime 1. Wipe the surface clean before installation to avoid (occupancy delay configuration, default:30s, can modify) ,R313WA will report un-pressure dust on the surface to affect the adhesion of the device. Note: 2.
  • Page 14 Assembled between the sponge and the steel base.
  • Page 15: Important Maintenance Instruction

    8. Important Maintenance Instruction Kindly pay attention to the following in order to achieve the best maintenance of the product: Keep the device dry. Rain, moisture, or any liquid might contain minerals and thus corrode electronic circuits. If the device gets ⚫...