Model:R313FC
Wireless Activity Timer
Wireless Activity Timer
R313FC
User Manual
Copyright© Netvox Technology Co., Ltd.
This document contains proprietary technical information which is the property of NETVOX Technology. It shall
be maintained in strict confidence and shall not be disclosed to other parties, in whole or in part, without written
permission of NETVOX Technology. The specifications are subject to change without prior notice.

Advertisement

loading
Need help?

Need help?

Do you have a question about the R313FC and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for netvox R313FC

  • Page 1 Copyright© Netvox Technology Co., Ltd. This document contains proprietary technical information which is the property of NETVOX Technology. It shall be maintained in strict confidence and shall not be disclosed to other parties, in whole or in part, without written...
  • Page 2: Table Of Contents

    Table of Content 1. Introduction ................................2 2. Appearance ................................3 3. Main Features ................................3 4. Set up Instruction ..............................4 5. Data Report ................................5 6. Installation ................................9 7. Relative Devices ..............................10 8. Important Maintenance Instruction ........................10...
  • Page 3: Introduction

    1. Introduction R313FC is a vibration alarm device for Netvox ClassA type device based on LoRaWAN open protocol. It can detect movement or vibration duration of the device and is compatible with LoRaWAN protocol. LoRa Wireless Technology: LoRa is a wireless communication technology dedicated to long distance and low power consumption. Compared with other communication methods, LoRa spread spectrum modulation method greatly increases to expand the communication distance.
  • Page 4: Appearance

    2. Appearance Indicator Function Key 3. Main Features  Compatible with LoRaWAN  2 section 3V CR2450 button battery powered  Activity Timer  Compatible with LoRaWAN Class A  Frequency hopping spread spectrum technology  Configuration parameters can be configured through third-party software platforms, data can be read and alarms can be set via SMS text and email (optional) ...
  • Page 5: Set Up Instruction

    4. Set up Instruction On/Off Power on Insert two sections of 3V CR2450 button batteries and close the battery cover Turn on Press any function key and the green and red indicator flash once. Turn off (Restore to factory setting) Press and hold the function key for 5 seconds and the green indicator flashes 20 times. Power off Remove Batteries.
  • Page 6: Data Report

    The device report interval will be programmed based on the default firmware which may vary. The interval between two reports must be the minimum time. Please refer Netvox LoRaWAN Application Command document and Netvox Lora Command Resolver http://loraresolver.netvoxcloud.com:8888/page/index to resolve uplink data.
  • Page 7 (4Bytes,Fixed 0x00) R313FType (1Byte) SetR313F 0x01_R313FA, Reserved 0x03 TypeReq 0x02_R313FB, (8Bytes,Fixed 0x00) 0x03_R313FC SetR313F Status Reserved 0x83 TypeRsp (0x00_success) (8Bytes,Fixed 0x00) R313FC 0x51 GetR313F Reserved 0x04 TypeReq (9Bytes,Fixed 0x00) R313FType (1Byte) GetR313F 0x01_R313FA, Reserved 0x84 TypeRsp 0x02_R313FB, (8Bytes,Fixed 0x00) 0x03_R313FC SetActive...
  • Page 8 (2) Read device configuration parameters Downlink: 0251000000000000000000 The device returns: 8251003C003C0100000000 (current device configuration parameters) (3) Configure device type = R313FB ( 0x01 = R313FA, 0x02 = R313FB, 0x03 = R313FC) Downlink: 0351020000000000000000 The device returns: 8351000000000000000000 (configuration succeeded) 8351010000000000000000 (configuration failed)
  • Page 9 Note: MaxTime=MinTime. Data will only be report according to MaxTime (MinTime) duration regardless BatteryVoltageChange value. Example#2 based on MinTime = 15 Minutes, MaxTime= 1 Hour, Reportable Change i.e. BatteryVoltageChange= 0.1V. MaxTime Sleeping (MinTime) sleeping sleeping sleeping Wakes up and Wakes up and Wakes up and Wakes up and Wakes up and...
  • Page 10: Installation

    6. Installation 8. Installation 1. Remove the 3M adhesive on the back of the Activity Timer Activity Timer (R313FC) is suitable for the following and attach the body to the surface of a smooth object (please scenarios:  Industrial Equipment do not stick it to a rough surface to prevent the device from ...
  • Page 11: Relative Devices

    7. Relative Devices Model Function Appearance R718MBA Send an alarm when detecting vibration or movement R718MBB Count the number of vibration or movement R718MBC Count the time interval of vibration or movement 8. Important Maintenance Instruction Kindly pay attention to the following in order to achieve the best maintenance of the product: •...