Page 1
This document contains proprietary technical information which is the property of NETVOX Technology and is issued in strict confidential and shall not be disclosed to others parties in whole or in parts without written permission of NETVOX Technology. The specifications are subjected to...
Table of Contents 1. Introduction ................2 2. Appearance ................. 2 3. Features ..................3 4. Set up Instruction ................ 3 5. Data Report ................. 5 5.1 Example of ReportDataCmd ..........6 5.2 Example of Report Configuration ........7 5.3 Example for MinTime/MaxTime logic......... 8 6.
1. Introduction R313WA is a Class A wireless 2-gang seat occupancy device based on standard LoRaWAN protocol. The R313WA will report to the gateway whenever one of the 2-gang seat occupancy sensor detects external pressure. It will also report to the gateway when the external pressure is gone.
3. Features ⚫ Compatible with LoRaWAN ⚫ 2 sections of 3V CR2450 button battery power supply ⚫ Detectable voltage and seat status occupancy ⚫ Simple operation and setting ⚫ Protection level IP30 ⚫ Compatible with LoRaWAN Class A ⚫ Frequency hopping spread spectrum technology ⚫...
Page 5
Note: Fail to join the network (1) Please remove batteries if the device is not used to save power. (when the device is on) (2) Please check the device verification information on the gateway with your platform server provider. Function Key Restore to factory setting / Turn off Press and hold for 5 The green indicator flashes for 20 times: success...
When the seat is taken, report 1. When the seat is not taken, report 0. Note: The reported data is decoded by the Netvox LoRaWAN Application Command document and Netvox LoRa Command Resolver http://www.netvox.com.cn:8888/cmddoc Data report configuration and sending period are as following: Current Change<...
5.1 Example of ReportDataCmd Fport: 0x06 Bytes Var (Fix = 8 bytes) Version DeviceType ReportType NetvoxPayLoadData Version– 1 bytes –0x01——the Version of NetvoxLoRaWAN Application Command Version DeviceType– 1 byte – Device Type of Device ReportType – 1 byte –the Presention of the NetvoxPayLoadData, according to the devicetype NetvoxPayLoadData–...
5.3 Example for MinTime/MaxTime logic Example#1 based on MinTime = 1 Hour, MaxTime= 1 Hour, Reportable Change i.e. BatteryVoltageChange=0.1V MaxTime MaxTime sleeping (MinTime) sleeping (MinTime) Wakes up and collect data Wakes up and collect data Wake up and collect data REPORTS 2.8V REPORTS 2.7V REPORTS 2.5V...
Page 10
Notes: (1) The device only wakes up and performs data sampling according to MinTime Interval. When it is sleeping, it does not collect data. (2) The data collected is compared with the last data reported. If the data change value is greater than the ReportableChange value, the device reports according to MinTime interval.
DetectionTime is the detecting period. (Please find further info regarding DisableTime and DetectionTime below.) (1) When R313WA detects pressure caused by the occupancy of the seat, it will report 1 (indicating the seat is taken) and other status (battery for example).
Page 12
While DetectionTime is 60 secs and DisableTime is 30 secs, pressure is detected during 25 sec. R313WA will restart pressure detect procedure (DetectionTime). No pressure is detected during next DetectionTime and R313WA therefore report un-pressure Triggered DetectionTime = 60 secs...
(occupancy delay configuration,default:30s, can the surface to affect the adhesion of the device. modify) ,R313WA will report un-pressure 2. Do not install the device in a metal shielded box or Note: other electrical equipment around it to avoid affecting When the seat is taken, report 1.
8. Important Maintenance Instruction Kindly pay attention to the following in order to achieve the best maintenance of the product: Keep the device dry. Rain, moisture, or any liquid might contain minerals and thus corrode electronic circuits. If the device ⚫...