LUTControl

This function allows you to apply the
● GenICam Node
Name
LUTEnable
LUTIndex
LUTValue
● IIDC2 Register
Register
Field
LUTEnable
Implemented
Value
LUTValueAll
Implemented
Value[0]
Value[1]
Value[2]
...
Value[4095]
Copyright © 2019 Toshiba Teli Corpotration, All rights reserved.
LUT(input: 12it, output: 12bit) to the output images.
arbitrary
Output
luminance
example of LUT setting
Length
Interface
Byte / [bit]
IBoolean
4
IInteger
4
IInteger
4
Length
Address
Byte / [bit]
0x206020
[31]
0x20603C
4
0x2FFFDC
[31]
0x300000
4
0x300004
4
0x300008
4
...
...
0x303FFC
4
136 / 172
Binarization
Input
luminance
Access
R/W
Sets the activation of LUT function.
R/W
Sets the input level of LUT.
R/W
Sets the output level of LUT.
Access
R
Returns the state whether the function is implemented.
R/W
Sets the activation of LUT function.
[0] : Off
[1] : On
R
Returns the state whether the function is implemented.
R/W
Sets the output level of LUT.
R/W
Sets the output level of LUT.
R/W
Sets the output level of LUT.
...
...
R/W
Sets the output level of LUT.
Description
Description