MAGUIRE WEIGH SCALE BLENDER Installation Operation & Maintenance page 76

Hide thumbs Also See for WEIGH SCALE BLENDER:
Table of Contents

Advertisement

B L E N D E R 
W E I G H
S C A L E
flow rate for the specified material (WT/TI).
CWT
CTI
This rate is used to calculate an exact time period to dump the required quantity of
material.
AWT
Both of these numbers are adjusted by the computer logic after each cycle as a means of
ATI
continuously calibrating the dispense times.
This rate correction takes place continuously and the battery-backed RAM maintains the
correct rate even when power is turned off.
If, for some reason, you were to set these numbers manually, (for example, if the load cells
are damaged and you want to adjust the VOLUMETRIC flow rate), an example of a proper
setting would be as follows: For a 1" auger feeder with a 60 RPM motor; this unit
dispenses 8 grams per revolution which is 8 grams per second. Since the _WT gram
number indicates tenths of grams (model 2xx) and the _TI number indicates interrupts (at
244 per second) then the proper numbers would be:
_WT 00080 and _TI 00244.
The computer automatically bumps both numbers up in value by doubling them both until
at least one number exceeds 16,000. The ratio (rate) is still the same but error correction
routines work better with higher numbers.
_MI (set AUTOMATICALLY each time power is turned on.)
RMI
NMI
_MI numbers are set to one half the amount of material, in grams, that can feed in one
CMI
second based on normal valid dispense rates. A valid rate is considered the normal
AMI
dispense rate that occurs under normal conditions with equipment functioning properly.
When a rate lower than half this actually occurs, it is assumed that an equipment
malfunction or loss of material has occurred. Under these circumstances, normal rate
correction routines are bypassed.
EXAMPLE:
about 8 grams per revolution or 8 grams per second. Since the _MI number is expressed
as tenths of grams, (model 2xx), half of this is expressed as (_MI 00040).
It is safe to use a _MI number that is too low but NOT safe to use
a number too high. Error correction routines will not work when
this number is too high.
This number is reset to 00001 every time power is turned on. After the system detects 10
good dispenses, (no retries, no bailouts), then the MI parameter is AUTOMATICALLY set
to 50 percent of current flow rate. The RATE CALIBRATION routine will also set this
parameter. Periodically, during production, if dispenses have occurred in a very uniform
manner for an extended period of time, the MI parameter is reset based on these
dispenses.
_NC (changes itself AUTOMATICALLY over time)
RNC
NNC
_NC is the allowable GRAM error within which NO flow rate corrections are made by the
CNC
software. Gram weight errors that are equal to, or less than, this number will be accepted
ANC
and no error corrections will take place. Since no equipment is perfect, we must accept
that a certain range of error is normal. To make corrections within this range only adds an
additional error due to hunting, and broadens the error range. This parameter controls and
prevents this. This parameter is adjusted automatically by the software according to the
For a 1" auger feeder with a 60 RPM motor drive, the normal metering rate is
M A G U I R E
P R O D U C T S ,
I N C .
76