allows the first digit to determine how long a reading is taken. A 1 in the first position
indicates ½ second per reading. 2 means 1 second, 3 means 1.5 seconds, up to 5 which is
2.5 seconds. The higher this number the slower the blend rate, but the more reliable the
readings.
KDF is used for load cell calibration weights, WDF for starting tare weight and component
dispense weights.
Change only if severe vibration causes problems
BER
BER is the BAILOUT ERROR weight. Dispenses are controlled by very accurate timing.
However, as a precaution, the weigh bin is constantly monitored during each dispense. If
bin weight is found to exceed target weight during the dispense, then a BAILOUT occurs.
This ends the dispense immediately just as if the end of the dispense time period had been
reached. This in no way effects the accuracy of the remainder of the cycle. The dispense
is checked and retries will occur if
required.
A bailout does not occur unless target weight is exceeded by the weight given in the
BAILOUT ERROR parameter. This is primarily to prevent vibration from causing a false
bailout during very small dispenses. We set this parameter to a default of 00200 (20 grams
or 200 grams). If vibration is causing false bailouts, then you may want to set a higher
value in this parameter.
If the BER parameter has a 1 in the last position, (BER 00201), then a printout will occur of
all cycle data anytime a bailout occurs for any single component. This is helpful if you want
to be aware of occurrences where dispenses significantly exceed target. This will be the
same information that you see when the PRINT flag is on (*54). A printer must be
connected.
CXT
Moves the decimal to the left on color and additive settings.
Change if you want less then 00.1 percent
AXT
_XT, is a number that will alter the meanings of the thumbwheel switches for COLOR
(CXT) or ADDITIVE (AXT). This number, when set, will be divided into the thumbwheel
setting; thereby reducing it's value. The only valid entries are 10 and 100. When set to
"00010" the decimal point is moved left one place and the setting is read as X.XX percent.
When set to "00100" the decimal point is moved left two places and the setting is read as
.XXX percent. This allows closer control where requested dispense is less than 1 percent.
When set to "00000", this parameter has no effect.
Allows for adding some ADDITIVE to one of the REGRIND portions
ROC
ROC indicates the PERCENT of one REGRIND that will be treated as natural when
ADDITIVE dispenses are calculated. If you feel it is necessary to ADD (or subtract) color
or additive to your regrind, this parameter will automatically see that this is accomplished.
The first digit is 0 to add, 1 to subtract. The second digit is the REGRIND component
number you will be making this adjustment for. The last 3 digits indicate the percent of this
Regrind component to add to, or subtract from, the Naturals when computing Additive
dispenses.
EXAMPLE: ROC set to (ROC 01020).
The first 0 means add. The 1 is component 1.
The 20 means take 20 % of component 1 (a Regrind) and ADJUST the total of all
NATURAL dispenses upward by this amount. Whatever amount of component 1, Regrind,
M A G U I R E