MAGUIRE WEIGH SCALE BLENDER Installation Operation & Maintenance page 46

Hide thumbs Also See for WEIGH SCALE BLENDER:
Table of Contents

Advertisement

B L E N D E R 
W E I G H
S C A L E
BATCH
and sound the ALARM. The process may also be programmed to sound the alarm but continue running.
This key is NOT FUNCTIONAL unless the last digit in the "FLG" parameter is set to 1 or 2. (xxxx1 or xxxx2).
To do this, see the MAINTENANCE section, PARAMETER TABLE, "FLG".
The ALARM SILENCE button on the side of the controller is the ONLY way to CONTINUE OPERATION after
a BATCH amount has been run.
Assuming a proper "FLG" parameter is set:
Press the BTCH key once to view the desired BATCH WEIGHT.
Display will say: BATCH INFORMATION Weight:
BATCH WEIGHT is the amount you wish to dispense before stopping and/or sounding the alarm.
Press again to view the CURRENT PORTION, of the batch, that has been dispensed.
Display will say: Portion:
CURRENT PORTION shows how much of the Batch Weight you have blended so far.
Press again to view the ACCUMULATED TOTAL weight of all batches dispensed.
Display will say: Total:
ACCUMULATED TOTAL is the sum weight of all batches that have been blended. This number will continue
to grow until it is manually cleared to zero, or it exceeds its maximum possible value.
Press again to view the total BATCH COUNT.
Display will say: Count:
BATCH COUNT is the total number of batches that have run.
This number will continue to grow until it is manually cleared to zero, or it exceeds its maximum possible
value.
Press again to return to normal operation.
When any of the above totals are being displayed, you may press the CE key to RESET that number to zero.
While all four totals can be cleared to zero manually, only the BATCH WEIGHT number can be entered
manually.
When the BATCH WEIGHT is being displayed, you may enter a NEW batch weight using the keypad. You
must enter a 5-digit number with leading zeros, if necessary. Maximum number that can be entered is
"59999".
The unit of weight that will be used is either POUNDS or KILOGRAMS as determined by the *89 option,
explained later.
While in operation, when the total is reached, the system will alarm and stop blending if the FLG parameter is
set to 00001. The system will alarm but CONTINUE running if the FLG parameter is set to 00002. Use the
ALARM SILENCE button (on the side of the controller) to silence the alarm. Pressing the BTCH key to view
the information will also silence the alarm.
If the system is programmed to STOP at the end of a batch, the ALARM SILENCE button MUST be pressed
to start blending the next batch. The First press of the ALARM SILENCE button will silence the alarm. The
Second press will start the next batch.
The EXIT key will exit the BTCH sequence at any point but will NOT cause the system to start a new batch.
If an additional 120-volt output is desired for an alarm, substitute a 4 or 7 for the 00001. 4 turns on the
Additive outlet, 7 turns on component 7 output.
If you have a printer connected, totals will print automatically. (See VIEW, * for details).
- This key allows you to blend a PRE-SELECTED WEIGHT of material, and then STOP running
#
#
#
NOTE: Fractional cycles are not blended. Total weight may be in over the
target by as much as one cycle weight.
M A G U I R E
#
P R O D U C T S ,
I N C .