Updating Controller Firmware - MAGUIRE WEIGH SCALE BLENDER Installation Operation & Maintenance

Hide thumbs Also See for WEIGH SCALE BLENDER:
Table of Contents

Advertisement

B L E N D E R 
W E I G H
S C A L E

Updating Controller Firmware

Updating the firmware within the 12-12 Controller can be accomplished through 2 different methods.
Method 1: USB Drive Update
1. This method uses a standard USB drive. There are 3 files that are required to perform a software
update to the 12-12 Controller. These files may be requested from Maguire Products and are
labeled:
UPDATER.BIN
912WFxxx.crc
912WFxxx.s28
When you are provided with these three files, they should be copied to a USB drive and placed in a
folder named: Maguire
2. Insert the USB drive into the USB port on the 12-12 controller. Note, the controller should be
powered on but should not be running cycles.
3. Enter into program mode. Press
4. Press
93. The display should say Checking Device...
5. If more than one firmware version is stored on the flash drive, Press
versions. If you only have a single copy of firmware stored on the flash drive the controller will default
to displaying that version.
Select Version:
WFxxxxx
6. When the firmware to loaded is displayed, press the CE key to begin the firmware transfer.
7. When Update Complete! is displayed, turn off the controller and turn on again. Clear All will display
if a version update was applied. The firmware update to the controller is complete.
Verifying:
[WFxxxxx]
▒ ▒ ▒ ▒ ▒ ▒ ▒ ▒
Do not turn off controller or remove the flash drive while firmware
is updating! Doing so may corrupt the controller's firmware.
22222
Updating:
▒ ▒ ▒ ▒ ▒ ▒ ▒ ▒
M A G U I R E
P R O D U C T S ,
to toggle between firmware
xxx/726
I N C .
108

Hide quick links:

Advertisement

Table of Contents
loading