Hot-Swap For Nvme Drives - Supermicro SuperServer 120U-TNR User Manual

Table of Contents

Advertisement

Hot-Swap for NVMe Drives

Supermicro Ultra servers support NVMe surprise hot-swap. For even better data security,
NVMe orderly hot-swap is recommended. NVMe drives can be ejected and replaced remotely
using the BMC Dashboard.
Note: If you are using VROC, see the
Ejecting a Drive
1. BMC Dashboard > Server Health > NVMe SSD
2. Select Device, Group and Slot, and click Eject. After ejecting, the drive Status LED
indicator turns green.
3. Remove the drive.
Note that Device and Group are categorized by the CPLD design architecture.
Slot is the slot number on which the NVMe drives are mounted.
Replacing the Drive
1. Insert the replacement drive.
2. BMC Dashboard > Server Health > NVMe SSD
3. Select Device, Group and slot and click Insert. The drive Status LED indicator flashes
red, then turns off. The Activity LED turns blue.
Chapter 3: Maintenance and Component Installation
VROC section
Figure 3-8. BMC Dashboard Screenshot
48