Environmental Requirements

A.3
ENVIRONMENTAL REQUIREMENTS
Operating Temperature:
Storage Temperature:
Operating Relative Humidity:
A.4

INPUT/OUTPUT PORTS

Ports 1 through 16: Fast Ethernet 100 Mbps
(100BASE-FX compliant) with MT-RJ connectors:
Slot for optional High Speed Interface Module (HSIM)
or Very High Speed Interface Module (VHSIM):
A.5
COM PORT PINOUT ASSIGNMENTS
The COM port is a serial communications port that supports Local Management or connection to a
UPS.
Table A-1
shows the COM port pin assignments:
Pin
Signal Name
1
Transmit Data (XMT)
2
Data Carrier Detect (DCD)
3
Data Set Ready (DSR)
4
Receive Data (RCV)
5
Signal Ground (GND)
6
Data Terminal Ready (DTR)
7
Request to Send (RTS)
8
Clear to Send (CTS)
A-2
Specifications
Table A-1 COM Port Pin Assignments
5°C to 40°C (41°F to 104°F)
-30°C to 73°C (-22°F to 164°F)
5% to 90% (non-condensing)
6H258-17 using multimode fiber only
6H259-17 using single mode fiber only
Slot accepts optional HSIMs or VHSIMs
that provide a variety of connections
Input/Output
Output
Output
Input
Input
NA
Output
Input
NA