Functions Related to Signal Tower Input

Determine Signal Tower Input
 There are two types of decisions for signal tower inputs, Normal and Flashing. Selection is done with WDS-WIN01. If there is
no flashing state, use "Normal".
Setting
Determination
Light on
Normal
Light off
Flashing
Light on
Light off
Flashing*
* Flashing is determined when there are two status changes within a defined period.
This period is called "SS seconds".
You can select "SS seconds" from three different time periods.
 Flashing (short): SS seconds = 0.7 seconds
 Flashing (medium): SS seconds = 1.5 seconds
 Flashing (long): SS seconds = 2.5 seconds
When the signal input status changes from "light off" to "light on", the result is
"light on" and information is transmitted.
When the signal input status changes from "light on" to "light off", the result is
"light off" and information is transmitted.
When the signal input repeatedly changes "light on" to "light off" to "light on" to
"light off" and so on, the result is "flashing" and information is transmitted. You
can select from 3 different time periods in WDS-WIN01 before flashing is
determined.
 Flashing (short)
 Flashing (medium)
 Flashing (long)
When the signal input status changes from "light off" to "light on", the result is
"light on" and information is transmitted.
When the signal input status changes from "light on" to "light off", the result is
"light off" and information is transmitted.