14 | Recording
14.2.4 Displaying online recording diagnosis

14.3 Event Logging

88 / 144
("statectrl_ok")
1.
To add a Recording Diagnosis element to a measurement sheet, drag a 'Bit-LED' ele-
ment from the Toolbox and drop it on measurement sheet.
2.
Drag channel 'statectrl_ok' from the Data Area and drop it on the 'Bit-LED' element.
The 'Bit-LED' element shows the state of received channel data in bit-representation. A
green highlighted channel means 0, a red highlighted channel means 1.
– Measurement correctly initialized, but recording threshold(s) not reached: 254
– Measurement correctly initialized, C 80 is recording data: 255
– Values less than 254 indicate an error state
Event Logging implements the possibility to observe a channel if short spikes are expec-
ted. With Event Logging, every occurrence of a user defined threshold (more complex
conditions are possible) leads to an event being raised. It is listed in a table along with its
time stamp, its ID and even with a text string freely definable in RaceCon.
Events are stored as text in logging data and displayed in WinDarab like Darab-Events.
Possible use cases are error entry, etc.
Configuration in RaceCon: