Bosch C 80 Manual page 63

Data logger and sensor interface
Table of Contents

Advertisement

Bosch Motorsport
Physical
(channel)
value
6.
Click 'Next' when done.
The third part of the "Characteristic Curve Wizard" opens.
Physical
limits of
channel
7.
Click 'Finish' when done.
8.
Enter channel name and description.
9.
Click 'OK' when done.
The channel is inserted into the C 80 Project Tree.
Channel is linked
to ANA05
Characteristic
curve for sensor
Input pin Pull-up
resistor is activated
Manual_C_80
Analog and Frequency Inputs | 12
Choose 'Ohm' to
enter datasheet
values directly.
Select physical
unit.
Enter resistance/
temperature pairs
from sensor data-
sheet here (the
3.01 kOhm pullup-
resistor is auto-
matically taken
into account)
Enter physical limits
of the channel
Choose data type of
the measurement
variable
This sensor does not
need offset
calibration
Enter name to auto-
matically create a
new measurement
sheet
Adjustment
is disabled
63 / 144

Advertisement

Table of Contents
loading

Table of Contents