Bosch C 80 Manual page 64

Data logger and sensor interface
Table of Contents

Advertisement

12 | Analog and Frequency Inputs
12.2.4 Configuring a multipoint adjustment
64 / 144
Available measurements for channel:
Measurement label
raw_name
raw_name_fi
name
name_fi
Note
Working with automatically created measurement sheets is explained in chapter 'Setting
up an online measurement [} 75]'.
Example: Measurement of wheel force
– Physical property 'wheel force' not directly measureable
– Load transfer through suspension kinematics
– Physical value at sensor position defined by vehicle
– Curve definition by online adjustment at vehicle
1.
Click on 'Measurement Sources' in the Toolbox.
2.
Expand the list of 'I/O Channels' by clicking on '+' in the C 80 Project Tree.
3.
Drag the 'Multipoint Adjustment' analog signal source from the Toolbox and drop it
on the desired analog input channel in C 80 Project Tree.
Drag + Drop
Manual_C_80
Function
mV value of sensor
filtered mV value of sensor
physical value of sensor
filtered physical value
Bosch Motorsport

Advertisement

Table of Contents
loading

Table of Contents