Bosch C 80 Manual page 68

Data logger and sensor interface
Table of Contents

Advertisement

12 | Analog and Frequency Inputs
12.2.6 Configuring a frequency input
68 / 144
– C 80 filters have constant, frequency independent delay
– Delay (e.g. 22 samples at 10 ms) is corrected during recording
– No delay filtered vs. unfiltered in recorded data
– Correction is (of course) not possible for real time data (display, online, PWM out)
– Use filtered data for recording, use unfiltered data for real-time
Example: measurement of wheel speed
– Pulse wheel attached to wheel
– Each passing tooth of pulse wheel triggers hall sensor
– Calculation of wheel speed with wheel circumference
1.
Click on 'Measurement Sources' in the Toolbox.
2.
To expand the list of 'I/O Channels', click on the '+' in the C 80 Project Tree.
3.
Drag the 'Velocity' digital signal source from the Toolbox and drop it on the desired
'REV' input channel in the C 80 Project Tree.
Drag + Drop
The 'Velocity Wizard' opens.
4.
Select the sensor type. The C 80 works with Halleffect and DF11 sensors.
Manual_C_80
Bosch Motorsport

Advertisement

Table of Contents
loading