Adding Optional U-Bend Reflector (Ptu Only); Attaching Burner Screen - (200M Btu Models Only) - Space-Ray PTS Series Installation And Operation Instructions Manual

Infrared radiant tube heater
Table of Contents

Advertisement

11.3)

ADDING OPTIONAL U-BEND REFLECTOR (PTU ONLY)

1. Place the U-Bend Reflector over the reflectors of each body section with the end resting next to the tube wire
hangers as shown.
2. Slide the speed clips on the reflector edges towards the end of the body section reflectors. Two speed clips
are required for each side of the U-Bend Reflector. Make sure that the speed clips fit tightly over both the U-
Bend Reflector and the reflector on each body section. Use two self-drilling screws to permanently secure
both sides to the reflectors.
3. Place the End Reflector flush with the U-Bend Reflector as shown. Note: Clearance between end of the U-
Bend Reflector and the U-Bend must be a minimum of 1". Secure by sliding speed clips onto the end
reflector edges. Evenly space the speed clips on the sides (two each side) and top (three each) of the
reflectors to provide a snug fit.
12.0)
ATTACHING BURNER SCREEN – (200M BTU MODELS ONLY)
A burner screen is assembled with the burner. If necessary, the burner screen must be field adjusted as shown
below before operation of the heater.
4. Pull burner screen forward from the gas manifold and slide screen over burner until the tab stops against
the rear of the burner cup (approximately 4 - 3/16" from the burner box) as shown below.
-26-
Form 43343330
May 2021

Advertisement

Table of Contents
loading