Connecting The Tiss System - Space-Ray PTS Series Installation And Operation Instructions Manual

Infrared radiant tube heater
Table of Contents

Advertisement

12.5)

CONNECTING THE TISS SYSTEM

Description: The TISS (Tube Integrity Safety System) is designed to shut the main burner off in the event that a
burnout occurs in the first 10ft. section of firing tube. Note: When replacing the firing tube a new TISS wire
assembly PN 44176510 (spring and spring retainer clamp not included) must also be installed.
Instructions:
1. Make sure that the gap between the burner box and end of reflector is 3" and the reflector is securely
attached to the reflector support bracket. Make adjustments if necessary.
Step 1
Failure to maintain 3" gap as shown will result in pre-mature TISS wire failure.
2. Un-roll the TISS wire assembly from the spool. Be careful not to kink the wires.
Step 2
Form 43343330
May 2021
-29-

Advertisement

Table of Contents
loading

Table of Contents