Stanford Research Systems SR830 Manual page 9

Dsp lock-in amplifier
Table of Contents

Advertisement

SR830 DSP Lock-In Amplifier
DATA STORAGE
SRAT (?) {i}
SEND (?) {i}
TRIG
TSTR (?) {i}
STRT
PAUS
REST
DATA TRANSFER
OUTP? i
OUTR? i
SNAP?i,j{,k,l,m,n}
OAUX? i
SPTS?
TRCA? i,j,k
TRCB? i,j,k
TRCL? i,j,k
FAST (?) {i}
STRD
INTERFACE
RST
IDN?
LOCL(?) {i}
OVRM (?) {i}
TRIG
STATUS
CLS
ESE (?) {i} {,j}
ESR? {i}
SRE (?) {i} {,j}
STB? {i}
PSC (?) {i}
ERRE (?) {i} {,j}
ERRS? {i}
LIAE (?) {i} {,j}
LIAS? {i}
page description
5-13
Set (Query) the DataSample Rate to 62.5 mHz (0) through 512 Hz (13) or Trigger (14).
5-13
Set (Query) the Data Scan Mode to 1 Shot (0) or Loop (1).
5-13
Software trigger command. Same as trigger input.
5-13
Set (Query) the Trigger Starts Scan modeto No (0) or Yes (1).
5-13
Start or continue a scan.
5-13
Pause a scan. Does not reset a paused or done scan.
5-14
Reset the scan. All stored data is lost.
page description
Query the value of X (1), Y (2), R (3) or θ (4). Returns ASCII floating point value.
5-15
5-15
Query the value of Display i (1,2). Returns ASCII floating point value.
5-15
Query the value of 2 thru 6 paramters at once.
5-16
Query the value of Aux Input i (1,2,3,4). Returns ASCII floating point value.
5-16
Query the number of points stored in Display buffer.
5-16
Read k≥1 points starting at bin j≥0 from Display i (1,2) buffer in ASCII floating point.
5-16
Read k≥1 points starting at bin j≥0 from Display i (1,2) buffer in IEEE binary floating point.
5-17
Read k≥1 points starting at bin j≥0 from Display i (1,2) buffer in non-normalized binary floating
point.
5-17
Set (Query) Fast Data Transfer Mode On (1 or 2) or Off (0).On will transfer binary X and Y
every sample during a scan over the GPIB interface.
5-18
Start a scan after 0.5sec delay. Use with Fast Data Transfer Mode.
page description
5-19
Reset the unit to its default configurations.
5-19
Read the SR830 device identification string.
5-19
Set (Query) the Local/Remote state to LOCAL (0), REMOTE (1), or LOCAL LOCKOUT (2).
5-19
Set (Query) the GPIB Overide Remote state to Off (0) or On (1).
5-19
Software trigger command. Same as trigger input.
page description
5-20
Clear all status bytes.
5-20
Set (Query) the Standard Event Status Byte Enable Register to the decimal value i (0-255).
ESE i,j sets bit i (0-7) to j (0 or 1). ESE? queries the byte. ESE?i queries only bit i.
5-20
Query the Standard Event Status Byte. If i is included, only bit i is queried.
5-20
Set (Query) the Serial Poll Enable Register to the decimal value i (0-255). SRE i,j sets bit i (0-
7) to j (0 or 1). SRE? queries the byte, SRE?i queries only bit i.
5-20
Query the Serial Poll Status Byte. If i is included, only bit i is queried.
5-20
Set (Query) the Power On Status Clear bit to Set (1) or Clear (0).
5-20
Set (Query) the Error Status Enable Register to the decimal value i (0-255). ERRE i,j sets bit i
(0-7) to j (0 or 1). ERRE? queries the byte, ERRE?i queries only bit i.
5-20
Query the Error Status Byte. If i is included, only bit i is queried.
5-20
Set (Query) the LIA Status Enable Register to the decimal value i (0-255). LIAE i,j sets
bit i (0-7) to j (0 or 1). LIAE? queries the byte, LIAE?i queries only bit i.
5-20
Query the LIA Status Byte. If i is included, only bit i is queried.
1-8

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents