Perkins 1300 EDi Series Workshop Manual page 202

Table of Contents

Advertisement

13
Peregrine EDi and 1300 Series EDi
Starter ring
To remove and to fit
Operation 13-3
To remove
Warning! For this operation eye protection must be used.
1 Before the starter ring is removed, note the position of the chamfer on the teeth.
2 To remove the starter ring, use a hammer and a chisel to break the ring. Ensure that the flywheel is not
damaged during this operation.
To fit
1 It is necessary to heat the starter ring to not more than 278 °C (500 °F) before it can be fitted to the flywheel.
Ensure that the chamfer on the teeth is in the same position as the original, and that the starter ring is fully
against the shoulder on the flywheel.
190
Workshop Manual, TPD 1353E, Issue 3
This document has been printed from SPI². Not for Resale