Proxim Edge MP-1015-CPE Hardware Installation Manual page 64

Table of Contents

Advertisement

82
54
83
60
84
68
85
76
86
85
87
95
88
107
89
120
90
135
: The Distance (m) is calculated by assuming the 60% of the 1st Fresnal to be clear.
Effective Isotropic Radiated Power (EIRP)
In countries like USA and Canada, radio can be installed with any directional antennas gain, as there is no Effective Isotropic
Radiated Power (EIRP) limit for the application of these systems for fixed point-to-point applications in the 5.8 GHz frequency
band. In other bands and in other countries, EIRP limits may apply. In the case of EIRP limits, use the lower values of either
(P
- L
+ G
) or the EIRP limit, within the
out
1
1
assure legal application. An EIRP limit is the maximum RF energy that can be transmitted as measured at the transmitting
antenna and is usually deterwmined by government regulations. For details, we recommend you to refer the Max EIRP values
listed under the Wireless Interface properties, in the Edge
The figure below shows the Proxim Link Calculator, available at http://support.proxim.com. Refer to Link Calculator - User
Guide to understand:
How to install the Link calculator
How to use the Link Calculator
TM
Edge
Multipoint and Quickbridge - Hardware Installation Guide
0.8
112
0.9
113
1.0
114
1.0
115
1.1
116
1.1
117
1.2
118
1.3
119
1.3
120
Link Budget
equation. You should check this calculation in both the directions to
Figure 9-5 Proxim Link Calculator
1697
4.8
1904
5.0
2136
5.3
2397
5.7
2689
6.0
3018
6.4
3386
6.7
3799
7.1
4263
7.6
TM
- Hardware Installation Guide.
Measuring Signal Performance
142
53.7
143
60.2
144
67.6
145
75.8
146
85.0
147
95.4
148
107.1
149
120.1
150
134.8
26.8
28.4
30.1
31.9
33.7
35.7
37.9
40.1
42.5
64