Page 1
BP/08/2004 OK*** 10/24/05 12:02 PM Page 1 BIOGENERICA S.R.L. Your Partner for Life Science and Research Products www.biogenerica.it L a b n e t I n t e r n a t i o n a l , I n c . BIOGENERICA SRL - Via Pescara 7 Int.17/23 - 95030 Mascalucia (CT) - Tel.
Page 2
BP/08/2004 OK*** 10/24/05 12:02 PM Page 2 BIOGENERICA S.R.L. Your Partner for Life Science and Research Products www.biogenerica.it BIOGENERICA SRL - Via Pescara 7 Int.17/23 - 95030 Mascalucia (CT) - Tel. 095 7916288 Fax 095 2246205 - email: info@biogenerica.it...
Page 3
BP/08/2004 OK*** 10/24/05 12:02 PM Page 4 BIOGENERICA S.R.L. Your Partner for Life Science and Research Products www.biogenerica.it 2-1000 µl 5000, 10000 µl 5000, 10000 µl BIOGENERICA SRL - Via Pescara 7 Int.17/23 - 95030 Mascalucia (CT) - Tel. 095 7916288 Fax 095 2246205 - email: info@biogenerica.it...
Fig. 1E. The disposable tips ensure maxi- 5 - DENSE AND VISCOUS LIQUIDS mum safety for the user and no cross contamina- 6 - LABNET PIPETTE TIPS tion between samples. To protect the user 7 - RECOMMENDATIONS from contamination by the tips, the BioPette™...
The pipette design enables the user to perform The figures for accuracy and precision given in the recalibration process according to the rules the following table were obtained using Labnet presented in section 8. tips. These figures are only guaranteed when Labnet tips are used.
BP/08/2004 OK*** 10/24/05 12:02 PM Page 10 BIOGENERICA S.R.L. Your Partner for Life Science and Research Products www.biogenerica.it the value down to 1/3 turn above the required set- • Press the pushbutton smoothly to the first ting. If the desired value is higher than the pre- stop, Fig.
To prevent this: BioPette™. - Press and release the pushbutton slowly and Some Labnet tips are color coded and corre- smoothly spond to the color on the pushbutton. - Never turn the pipette upside down...
BP/08/2004 OK*** 10/24/05 12:02 PM Page 14 BIOGENERICA S.R.L. Your Partner for Life Science and Research Products www.biogenerica.it • Do not pipette liquids with temperatures Recalibration conditions: above 70°C. • Ambient temperature and the temperature of the pipette, tips and liquid should be within •...
BP/08/2004 OK*** 10/24/05 12:02 PM Page 16 BIOGENERICA S.R.L. Your Partner for Life Science and Research Products www.biogenerica.it • Remove the pipetting pushbutton, (Fig. 4A) Immerse the tip deeper according to the instructions. Warning: The pipetting pushbutton consists of • The pipette tip is incorrectly pressed onto the 2 parts: the knob (Fig.
The shaft of the 5000 and 10000 models should be autoclaved without the filter. If the problem continues after carrying out the above steps, contact your Labnet representa- tive. Before returning the pipette, please ensure that the pipette is completely free of any chemical,...
N: Ejector pushbutton P4803-1000 1000 µl tips, racked P3998 5000 µl tips, bulk pack can be ordered from a Labnet representative (type of the pipette and name of the part for this L943 10000 µl tips, bulk pack pipette should be specified).
Need help?
Do you have a question about the BioPette 5A and is the answer not in the manual?
Questions and answers