14 Receiver LED Information

Normal operation
#
LED indication
1
2
3
˜ ™ ˜ ™ ™
1
˜ ™ ™ ˜ ™
2
˜ ™ ™ ˜ ˜
3
˜ ˜ ˜ ™ ˜
4
˜ ˜ ˜ ™ ™
5
Pre-reset:
˜ ™ ™ ˜ ˜
6
˜ ™ ™ ˜ º
7
Blanking:
˜ º ˜ ™ ™
8
˜ º ™ ˜ ™
9
Single/double break:
˜ ™ ™ ˜ º
10
˜ ™ ™ ˜ º
11
˜ ™ ˜ ™ º
12
2TLC172015M0201, rev. D
Name of LED
1
2
3
4
5
4
5
OSSD on
OSSD off
Waiting for Reset
Alignment mode - best optical alignment
Short circuit on output
Waiting for reset
Pre-reset button pushed. Waiting for reset. 1 flash/sec.
Floating blanking active
Floating blanking active, object in protective field
Waiting for manual restart of single/double break function sequence
after power on or after interruption of the protective field while the
machine is working. 2 flashes/sec.
Normal operation of single/double break function (load/unload).
3 flashes/sec.
Normal operation of single/double break function (machine operation).
3 flashes/sec.
Colour
Green
Yellow
Green
Red
Yellow
Description