4.5 Setting up Scan Codes

The Focus II transmitter and receiver has the possibility of coding selection, to minimize interference when
two transmitters can reach one receiver.
NB! Both transmitter and receiver shall be set to the same code. All LEDs on transmitter / receiver flash
twice when code B is set correct, when powering up. Code A will flash once. Please make sure that the total
length of the cable between the transmitter and receiver (required when coding is used, see 5.6) does not
exceed 100 m.
Transmitter
Receiver

4.6 Choice of Reset Procedure

Reset of Focus II barrier may be reached in three different ways:
A
Automatic reset: The barrier is reset directly after the protection area has become clear. Change-over
switch No. 8 is set in position "On" (see 4.4).
B
Manual reset: The barrier is reset when the protection area is clear and the reset button has been
pressed and released. Change-over switch No. 8 is set in position "Off" (see 4.4).
Pre-reset: The barrier is reset when, f  i rst, the pre-reset button, which is normally placed inside
C
hazardous area, has been pressed (the yellow LED 5 in receiver is blinking) and, thereafter, if the
protection area is clear, within 8 seconds the reset button outside the area has been pressed and
released. (See 4.4 and 8)
2TLC172015M0201, rev. D
Switch 3
OFF
No code (exclusion of dip 4)
ON
Code on
Switch 4
OFF
Code A
ON
Code B
Switch 7 Upper bank
OFF
Code A
ON
Code B
Switch 7 Lower bank
OFF
No code (exclusion of dip 7 upper bank)
ON
Code on
20