Test Procedure Log - ABB Focus II FII-4-14 Series Original Instructions Manual

Light grid / light curtain
Table of Contents

Advertisement

24 Test procedure log

Check point
Disable the guarded machine. Apply
power to the Focus II system, check
that LED 1 and 3 are lit on the
receiver.
Visually inspect the machine to
ensure that access to the hazardous
area is only through the Focus II
system.
Verify that the mounting distance of
the Focus II system is equal to or
greater than the minimum distance.
See 3.3 or 3.4
Check for signs of damage in the
Focus II system installation, the
cables and wiring. If something are
damaged, secure the machine and
report.
Interrupt the Focus II system
detection zone with the supplied test
tool. See 16
Start the machine. Check that the
machine stops when the test tool is
inserted to the detection zone, and
it is not possible to restart when the
test tool is in the detection zone.
Verify that the safety system is
stopping the machine fast enough
otherwise adjust or increase the
distance.
If the safety devices on the machine
fails any of these tests, secure
machine and report.
Date and Signature:
_______________
2TLC172015M0201, rev. D
Condition
£ Pass
£ Fail
£ Pass
£ Fail
£ Pass
£ Fail
£ Pass
£ Fail
£ Pass
£ Fail
£ Pass
£ Fail
£ Pass
£ Fail
£ Pass
£ Fail
__________________________________________________
Comments