Arcconf Rescan; Arcconf Romupdate - Adaptec 5405Z User Manual

Raid controller
Hide thumbs Also See for 5405Z:
Table of Contents

Advertisement

Desired size in MB.
RAID# is the RAID level for the logical drive 0, 1, 5, 5EE, or 10.
Note:
The CHANNEL# and DRIVE# parameters is the list of devices that will contain the target
modification object.
Channel# is the channel number for the device.
Drive# is the device_ID (device number) for the device.
Note:
Channel and device_ID are repeatable parameters.
Noprompt is an optional parameter that overrides the user prompt.
Example
ARCCONF MODIFY 1 FROM 2 TO 2048 0 0 123 0 124 0 117

arcconf rescan

Enables the controller to check for the removal of any disk drives in the ready state and to check
for the connection of any new disk drives to the controller. The command returns when the
rescan is complete.
Syntax
ARCCONF RESCAN <Controller#>
Parameters
Controller# is the controller number
Example
ARCCONF RESCAN 1

arcconf romupdate

Allows new firmware and BIOS to be flashed to the controller. A reboot is required for the new
firmware to take effect.
Note:
This function is only supported in Windows and Linux.
1
Be sure to copy the *.UFI update files from the CD and not from the BIOS/Firmware
2
update diskettes.
Syntax
ARCCONF ROMUPDATE <Controller#> <BaseName>
Parameters
Controller# is the controller number
BaseName is the name of the ROM image basename or the fully qualified name if you have a
set of controller ROM images.
Note:
All UFI files must be in the same directory prior to invoking ARCCONF. If you are copying
UFI files from floppy images, be sure to check all images.
Example
ARCCONF ROMUPDATE 1 AC2200
ARCCONF ROMUPDATE 1 AC220001.UFI
Chapter 2: Using the Command Line Utility
19