Baxi LUNA3 SYSTEM HT 1.180 MP Installers And Users Instructions page 60

Wall-mounted condensing boilers
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 36
Luna3 sYsteM ht 1.330 Mp
Gas consumption at 15 °c
1013 mbar
PCI
Consumption at max. heat output
Consumption at min. heat output
table 2a
Luna3 sYsteM ht 1.240 Mp
Gas consumption at15 °c
1013 mbar
PCI
Consumption at max. heat output
Consumption at min. heat output
table 2b
Luna3 sYsteM ht 1.180 Mp
Gas consumption at 15 °c
1013 mbar
PCI
Consumption at max. heat output
Consumption at min. heat output
table 2c
Gas boiler model
LUNA3 SySTEM HT 1.330 MP
LUNA3 SySTEM HT 1.240 MP
LUNA3 SySTEM HT 1.180 MP
table 3
InstructIons pertaInInG to the InstaLLer
G20 - 2h - 20 mbar
34.02 MJ/m
3
3.59 m
/h
3
1,06 m
/h
3
G20 - 2h - 20 mbar
34.02 MJ/m
3
2.61 m
/h
3
0.74 m
/h
3
G20 - 2h - 20 mbar
34.02 MJ/m
3
1.84 m
3
/h
0,44 m
3
/h
cLocKWIse
parameters 608
regulation screw
(%) (rpm)
(V) turns
Gas G20
3
50
2
55
1
40
60
G31 - 3p - 37 mbar
46.3 MJ/kg
2.64 kg/h
0.78 kg/h
G31 - 3p - 37 mbar
46.3 MJ/kg
1.92 kg/h
0.54 kg/h
G31 - 3p - 37 mbar
46.3 MJ/kg
1.35 kg/h
0,33 kg/h
parameters 611
(rpm)
Gas G31
Gas G20
Gas G31
35
4200
3500
35
4600
4000
40
3900
3350
925.916.2 - GB

Advertisement

Table of Contents
loading

This manual is also suitable for:

Luna3 system ht 1.240 mpLuna3 system ht 1.330 mp

Table of Contents