Fan Operation - Daikin AIRHUB Operation Manual

Touch controller (linear and on/off system)
Table of Contents

Advertisement

8.

Fan Operation

(1) Airflow volume can be selected from the main Operation Screen.
(2) Tap to select the Airflow.
(3) Tap the required airflow level based on your preference.
(Fan settings are only available for On/Off control)
•To confirm the selected Airflow, tap anywhere on the screen. If no
selection is made or the screen is not touched for a period of 7 seconds
the Sliding Bar will close automatically.
(4)
icon is always displayed for the linear control version. Tap on
"OptiZone" a message will pop up on screen explaining that the airflow
rate is automatically controlled by your Linear Touch Control System, Tap
"OK" then message will disappear.
Fan Operation
Linear system
On/Off system
(2)
37
Airside function
•Airside function is set by the installer during the commissioning phase. The fan
speed is automatically adjusted & is based on the number of active zones.
Auto fan operation
•AUTO fan settings (Auto High / Auto Med / Auto Low) will only operate when the
"Indoor sensor" is selected. When the "Indoor sensor" is not been selected the
AUTO fan function will operate the same as standard settings - High / Med / Low
•When AUTO fan settings (Auto High / Auto Med / Auto Low) is selected, the
indoor fan stops when the required room temperature is achieved and operates
when the room temperature deviates outside the room temperature setting
range.
•Whilst the room temperature is within the set room temperature range & after a
duration of 6 minutes the indoor fan will operate for a period of 30 seconds or
more (depending on model) to allow the indoor sensor located in the indoor unit
to sample the room air temperature.
(4)