Outdoor unit installation
Magnetic ring installation
Please note that different models are supplied with a different
combination of magnetic rings that must be installed by a
licensed electrician. These magnetic rings (if required) help to
minimise electro magnetic interference, which if not installed
correctly may impact television and radio operation.
The installer must install the magnetic rings inside the outdoor
unit electrical cover by clipping around the wires (as explained
below) located approximately 4cm from the terminal block and
securing in place with a cable ties.
Models KSV50HRH, KSD50HRH, KSV50HWH & KSD50HWH are
supplied with two magnetic rings that must be clipped around
both the power supply in wires (L, N & Earth) and the
interconnecting wires (1(L), 2(N), S & Earth) leading to the
indoor unit.
Fig. 19a
DR
1(L)
2(N)
S
4cm
Y/G
Magnetic ring
INDOOR UNIT
Models KSV25CRH, KSV25HRH, KSD25HRH, KSV25HWH,
KSD25HWH, KSV35CRH, KSV35HRH, KSD35HRH,
KSV35HWH, KSD35HWH, KSV71CRH, KSV71HRH,
KSD71HRH, KSV71HWH, KSD71HWH, KSV90HRH,
KSD90HRH, KSV90HWH & KSD90HWH do not require
magnetic rings to be tted.
Fig. 19b
DR
1(L)
2(N)
Y/G
INDOOR UNIT
14 Outdoor unit installation Kelvinator Air Conditioning
N
L
4cm
Magnetic ring
POWER SUPPLY
N
L
S
POWER SUPPLY
Electrical connection
Wiring diagram
Indoor unit terminal block
1(L)
2(N)
S
Key:
1(L) = Live (Brown)
2(N) = Neutral (Blue)
S = Signal (White)
= Earth (Yellow & Green)
Installation of DRED network cable
The following models are equipped with a RJ45 Demand Response
connection socket to facilitate demand response control by your
electricity provider:
KSD25HRH, KSD35HRH, KSD50HRH, KSD71HRH, KSD90HRH,
KSD25HWH, KSD35HWH, KSD50HWH, KSD71HWH, KSD90HWH
Please refer to your electricity provider for more information about
DRED.
The DRED socket is located inside the outdoor unit near the
terminal block, and is labelled "DR", refer to
Connect the demand response cable into the DRED socket labelled
DR, ensure that a click is heard to con
Secure the demand response cable in the cable clamp, then
terminal block cover and secure with screws.
Outdoor unit terminal block
1(L)
2(N)
S
L
N
Power supply
(3)
re 19.
t has locked into place.