Indoor unit installation

Drilling the wall

1.
Choose the hole position to be either on the left or right side
of the installation plate and mark the position according to the
dimensions shown in gure 2. Note most simple installation is
with hole on the right side.
2.
Drill the piping hole with a hole core drill of the following
size: 65mm for models: KSV25CRH, KSV25HRH,
KSD25HRH, KSV25HWH, KSD25HWH, KSV35CRH,
KSV35HRH, KSD35HRH, KSV35HWH, KSD35HWH.
75mm for models: KSV50HRH, KSD50HRH, KSV50HWH,
KSD50HWH, KSV71CRH, KSV71HRH, KSD71HRH,
KSV71HWH, KSD71HWH.
90mm for models: KSV90HRH, KSD90HRH, KSV90HWH,
KSD90HWH.
3.
Drill the hole with slight (5-10mm) downward angle from indoor
to outdoor side so that the outside end is lower than the inside
end to help drainage, see
4.
Insert a wall pipe or other means of protection to prevent the
pipes and electrical wires from toughing sharp edges within
the wall.

Connective pipe installation

1.
For the left-hand and right-hand piping, remove the pipe
cover from the side panel.
2.
For the right back and left back piping, install the piping
as shown.
NOTE: Bundle the pipes, connecting cable, and drain hose
with tape securely, evenly as shown in gure 4 on the right.
The drain connection can be on the right side, left side or
both. If choosing to drain from both sides, another drain pipe
will need to be supplied by the installer. If choosing one side
drainage connection, make sure the drain hole on the other
side is well plugged. For 2.5kW & 3.5kW models, if choosing
left-hand or left-back piping, please choosing left side
drainage connection. The connection of the drain pipe hose
must be connected by a qua
these instructions to prevent leakage.
3.
Attach the drain hose to the underside of the refrigerant pipes
with adhesive vinyl tape.
4.
Bundle the pipes, connecting cable, and drain hose with tape
securely, evenly as shown in Fig. 4.
5.
Pass them through the wall hole.
6.
Ensure that the drain hose has a continual downward fall from
the indoor side to the outdoor side to ensure the wate
out smoothly. Failure to do this can result in water gathering in
and leaking from the indoor unit.
caution
WARNING
Do not put anything inside the condensate drain pan (refer to
ure 5), as this space is required to collect the condensate
prior to draining out of the indoor unit.
ure 3.
d installer in accordance with
Fig. 3
Fig. 4
Move and tape
the drain hose
with piping in
a position as
mentioned in
Fig. below
Cover for
the piping
Right piping
Left piping
Indoor unit
Fig. 5
s
Drain hose
Kelvinator Air Conditioning Indoor unit installation 7
Indoor
Wall
Outdoor
5-10mm
Rubber plug
Cover for
the piping
Left back
piping
Condensate
drain pan
Connective
Pipe room
cable
Connective
pipe
Wrapping
belt
Cover for
the left piping

Advertisement

Table of Contents
loading

Table of Contents