Advertisement

Quick Links

Installation and Operating instructions for
Industrial PC series
C61xx from -0060
Version: 3.0
Date:
2018-02-16

Advertisement

Table of Contents
loading

Summary of Contents for Beckhoff C61 Series

  • Page 1 Installation and Operating instructions for Industrial PC series C61xx from -0060 Version: 3.0 Date: 2018-02-16...
  • Page 3: Table Of Contents

    Switching the Industrial PC on and off First switching on and driver installation Maintenance Cleaning the Industrial PC Replacing the battery on the motherboard Servicing Shutting down Disposal Troubleshooting Fault correction Service and Support Beckhoff's branch offices and representatives Beckhoff headquarters Beckhoff Support Beckhoff Service C61xx...
  • Page 4 Table of contents Assembly dimensions Appendix Technical data Approvals FCC: Federal Communications Commission Radio Frequency Interference Statement FCC: Canadian Notice C61xx...
  • Page 5: General Instructions

    All the components are supplied in particular hardware and software configurations appropriate for the application. Modifications to hardware or software configurations other than those described in the documentation are not permitted, and nullify the liability of Beckhoff Automation GmbH & Co.KG. Delivery conditions In addition, the general delivery conditions of the company Beckhoff Automation GmbH &...
  • Page 6: Description Of Safety Symbols

    General instructions Description of safety symbols The following safety symbols are used in this operating manual. They are intended to alert the reader to the associated safety instructions. This symbol is intended to highlight risks for the life or health of personnel. Danger This symbol is intended to highlight risks for equipment, materials or the environment.
  • Page 7: Operator's Obligation To Exercise Diligence

    General instructions Operator's obligation to exercise diligence The operator must ensure that • the Industrial PC is only used for its intended use (see also Product Description). • the Industrial PC is in a sound condition and in working order during operation.
  • Page 8: Product Description

    Product Description Product Description Appropriate Use The C61xx series Industrial PCs are designed for mounting in control cabinets for machine and plant engineering applications. Structure Example: front view of Industrial PC C6140 Opening the housing The C61xx series Industrial PCs can be opened by removing the cover (see top photograph).
  • Page 9: Interfaces From C6140-0060/ C6150-0060

    Product Description Interfaces from C6140-0060/ C6150-0060 ATX motherboard X116 X105 interfaces X104 X117 X115 X112 X113 X103 X118 X109 X111 X114 X119 X108 X110 PS/2 connections PS/2 The upper PS/2 connector (X104) allows a PS/2 mouse to be used, while a PC keyboard can be connected to the lower PS/2 connector (X103).
  • Page 10: Additional Interfaces (Optional)

    Product Description Additional Interfaces (optional) Connection of a control panel (optional) CP-Link If a CP-Link interface card is fitted, a control panel can be connected to the Interface card Industrial PC. The two coaxial connectors are connected here with the control panel, and the 26-pin sub-D socket connector is connected to the lower PS/2 connection and to the serial COM1 interface.
  • Page 11: Installation Instructions

    4. Please keep the associated paperwork. It contains important information for handling the unit. 5. Check the contents for visible shipping damage. 6. If you notice any shipping damage or inconsistencies between the contents and your order, you should notify Beckhoff Service. C61xx...
  • Page 12: Installation Of The Pc In The Control Cabinet

    Installation Instructions Installation of the PC in the control cabinet The C61xx Industrial PCs are designed for mounting in control cabinets for machine and plant engineering applications. The ambient conditions specified for operation must be observed (see chapter Technical data). Preparation of the control Four holes for the fixing bolts have to be provided in the control cabinet cabinet...
  • Page 13: Power Supply Connection

    Installation Instructions Power Supply Connection The 5-pin CAGE CLAMP plug connector and mounting flange illustrated is located on the PC housing in order to connect the power supply. Socket at the PC housing Technical data Connecting socket Number of contacts Contact spacing 5 mm Minimum conductor cross-section...
  • Page 14: Current Carrying Capacity Of The 24 V Power Supply Unit

    Installation Instructions Current carrying capacity of the 24 V power supply unit all Industrial PCs Output voltages from Current loading the 24 V power supply maximum unit +5 V 25 A -5 V +12 V 10 A -12 V 1.5 A Fitting the Power Supply Cable Coding pieces The connectors are coded differently at the factory, using snap-on coding...
  • Page 15 Installation Instructions Pin assignment and cable requirements Pin assignment There is an adhesive label with the pin assignments on the top of the female plug connector. The minimum permitted conductive cross- section is 1.5 mm², fused for 10 A (AWG 16). Industrial PCs with 100-240 V , 50-60 Hz power supply unit Pin assignment for the...
  • Page 16: Connecting Devices

    Installation Instructions Connecting devices The power supply plug must be withdrawn! Warning Please read the documentation for the external devices prior to connecting them. During thunderstorms, plug connector must neither be inserted nor removed. When disconnecting a plug connector, always handle it at the plug. Do not pull the cable! Connecting cables The connections are located at the top of the Industrial PC and are...
  • Page 17: Operating Instructions

    Operating Instructions Operating Instructions Please also refer to chapter General instructions. Switching the Industrial PC on and off The Industrial PC does not have its own mains switch. The Industrial PC Switch on will start when the equipment is switched on, or when it is connected to the power supply.
  • Page 18: Maintenance

    Operating Instructions Maintenance Please also refer to chapter General instructions. Cleaning the Industrial PC Switch off the Industrial PC and all connected devices, and disconnect the Industrial PC from the power supply. Danger The Industrial PC can be cleaned with a soft, damp cloth. Do not use any aggressive cleaning materials, thinners, scouring material or hard objects that could cause scratches.
  • Page 19: Troubleshooting

    Nothing happens after the Industrial No power supply to the Industrial Check power supply cable. PC has been switched on Other cause. Call Beckhoff Service. The Industrial PC does not boot Floppy disk or CD in the drive. Remove floppy disk or CD fully and press any key.
  • Page 20: Service And Support

    Fax: +49(0)5246/963-198 e-mail: info@beckhoff.com Beckhoff Support Support offers you comprehensive technical assistance, helping you no only with the application of individual Beckhoff products, but also with other, wide-ranging services: • world-wide support • design, programming and commissioning of complex automation systems •...
  • Page 21 Assembly dimensions Assembly dimensions The following pages show diagrams of the Industrial PCs, with dimensions in mm. The assembly of the unit must take place with the orientation diagrammed here. Warning Industrial PC C6140 Depth : 265 mm C61xx...
  • Page 22 Assembly dimensions The assembly of the unit must take place with the orientation diagrammed here. Warning Industrial PC C6150 Depth : 265 mm C61xx...
  • Page 23 Appendix Appendix Technical data Industrial PC C6140 Dimensions (W x H x D): 383 x 362 x 265 mm Weight: 14 kg (basic configuration) Dimensions (W x H x D): 383 x 423 x 265 mm Industrial PC C6150 Weight: 15 kg (basic configuration) Do not use the PC in areas The Industrial PC may not be used in areas of explosive hazard.

This manual is also suitable for:

C6140C6150

Table of Contents