Code
27
ERROR_CAN_SAFETY
28
Cage ERROR_ANALOG
Cage Weigh Channel 1
29
Disconnected
Cage Weigh Channel 2
30
Disconnected
31
Tilt Sensor Disconnected
English/USA – 11/13
Original instructions
Fault
The control system has
detected an error in the
communication between the
base and cage
Error on one of the analogue
inputs to the cage PLC
The channel 1 cage weigh
module is disconnected or
faulty
The channel 2 cage weigh
module is disconnected or
faulty
The tilt sensor is disconnected
or faulty
Operating & Safety Instructions
Description
Check that there is around 60Ohms
between CANH and CANL anywhere on
the network
Check there are no short circuits
between CANH and CANL anywhere on
the network
Check address dials are set correctly
Check screen for further fault codes
Diagnose further using the service tool
Check the module is connected
Check the wiring from the cage panel
to the module
Check the module is connected
Check the wiring from the cage panel
to the module
Check the sensor is connected
Check the wiring from the base box to
the sensor
Height Rider/SP Series
Action
47