4.3.5
SiOPS
TM
- LOAD SENSING CONSOLE (If fitted)
This machine incorporates a load sensing cage console that senses if the operator has been pushed or
has fallen against the console. If the load applied to the front of the console is greater than the pre-
determined amount, the footswitch will be disabled to increase operator safety and reduce the
possibility of sustained involuntary operation of the cage controls.
Note: The green button will illuminate once the footswitch has been disabled, but continues to be
available for use at all times. This allows the operator to use the cage control functions and
manoeuvre the machine to a safe position.
To reset the footswitch:
1)
Release the load from the front of the console.
2)
Ensure cage controls are in the neutral position and clear of objects.
3)
Raise foot clear of footswitch then lower foot onto footswitch.
4)
Footswitch is now active and full control has been restored.
Note: If SiOPS
warning beacon will flash (If fitted, located on underside of the cage) and a warning
announcement will sound until the footswitch is reset as described previously.
English/USA – 11/13
Original instructions
WHEN OPERATING THIS MACHINE THE USER MUST BE AWARE OF ANY
OVERHEAD OBSTRUCTIONS.
TM
has been activated and the footswitch is not reset within 15 seconds, then the blue
Height Rider/SP Series