Cold Climates – CPI Setting - Proflame 2 Remote Control
Use the CPI setting during cold weather, otherwise the
fireplace may have a hard time starting up and establishing a
flame.
The CPI (Continuous Pilot Ignition) setting will keep the
firebox and fireplace exhaust vent warm during cold weather.
When the firebox and exhaust vent are warm, exhaust
gasses will readily flow out of the firebox.
If the firebox and venting are too cold, there is resistance due
to the heavy cushion of cold air, and combustion gasses may
not rise into the exhaust vent, thus causing the fireplace to
cycle or Lockout (if this happens see Lockout Reset
Procedures below).
To switch from IPI to CPI Mode:
1. Turn the fireplace OFF using the ON / OFF Key.
3. Press UP on the UP / DOWN
Arrow Key.
Display will show CPI.
The module in the fireplace will
beep once to confirm command.
Lockout Reset Procedures – Proflame 2
If the fireplace has cycled too many times in a short period of time, it will shut down and become unresponsive to any
new command. The LED light on the Proflame 2 module in the fireplace will be flashing red.
This condition is a Lockout state.
Lockout Reset Procedure:
Disconnect power from the Proflame 2 module in the fireplace for 10 seconds. This includes removing the backup
batteries.
Once the 10 second interval has passed, reconnect power and reinstall backup batteries. The pilot should now try to
light.
If the fireplace does not come on, call your fireplace technician.
2. Press the Mode Key. Display will appear as below.
(INTERMITTENT PILOT) MODE:
Repeat steps one and two, and then press
DOWN on the UP / DOWN Arrow Key.
The module in the fireplace will beep once to
confirm command.
LCD Display
ON / OFF Key
Thermostat Key
UP / DOWN Arrow Key
Mode Key
TO RETURN TO IPI