Omron H7EC Manual page 113

Self-powered totalizer
Hide thumbs Also See for H7EC:
Table of Contents

Advertisement

Settings for Advanced Functions
Note: When using as a tachometer, switch to the tachometer configuration using the procedure given on page 124.
Settings that cannot be performed with the DIP switch are performed with the operation keys.
Power ON
(See note 1.)
(See note 2.)
3s min.
3s min.
Note: 1. If the mode is switched to the function setting mode during operation, operation will
For details on operations in run mode, refer to page 37.
The characters displayed in reverse video are the initial values.
When performing settings with operation keys only, set pin1 of the DIP switch to OFF (factory setting).
If pin 1 of the DIP switch is set to ON, the setting items indicated by
Set each setting item using the
Tachometer
output
mode
(HI-LO)
(AREA)
Counting
speed
(30Hz)
(10kHz)
Decimal
point
position
(No decimal
(One digit
point)
after decimal
point)
Prescale
value
(0.001)
(1.000)
Average
processing
(No aver-
(Average
age pro-
of 2 meas-
cessing)
urements)
Auto-zero
time
(0.1s)
(99.9s)
Startup
time
(0.0s)
(99.9s)
NPN/PNP
input mode
(NPN
(PNP
input)
input)
Display
color
(Red)
(Green)
Output
allocation
Note: Displayed for H7CX-AU@ models
Key protect
level
(KP-1)
(KP-2)
Multifunction Preset Counter
continue.tion, operation will continue.
2. Changes made to settings in function setting mode are enabled for the first time when
the mode is changed to run mode. Also, whensettings are changed, the counter is re-
set (measured values initial-ized and output turned OFF) on returning to run mode.
keys.
(HI-HI)
(LO-LO)
(Two digits
(Three digits
after decimal
after decimal
point)
point)
(99.999)
(Average
(Average
of 4 meas-
of 8 meas-
urements)
urements)
(Red-green) (Green-red)
(KP-3)
(KP-4)
(KP-5)
H7CX (Tachometer Function)
will not be displayed.
C-119

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

H7eH7etH7erH7e n series