Omron H7EC Manual page 110

Self-powered totalizer
Hide thumbs Also See for H7EC:
Table of Contents

Advertisement

Total and Preset Counter Operation
The H7CX has a total counter, separate from the 1-stage preset counter, for counting the total accumulated value.
Reset/reset 1
Total reset/reset 2
Present value
0
999999
Total count value
0
Note: The full scale (FS) for H7CX 4-digit models is 9999.
Batch Counter Operation
The H7CX has a batch counter, separate from the 1-stage preset counter, for counting the number of times the count has been completed.
Reset 1
Reset 2 (batch
counter reset)
Set value
Present value
0
OUT2
Batch count set value
Batch count value
0
OUT1 (batch output)
Note: The above is for when the output mode is C.
Note: 1. The batch count value is held at 0 during batch counter reset input.
2. If the batch count set value is 0, batch count will be performed but there will be no batch output.
3. The batch count value returns to 0 when it reaches 999,999 (9,999 for 4-digit models).
4. Once batch input has been turned ON, it will return to the ON state after power interruptions.
5. If the batch count set value is changed from a value that is greater than the batch count value to one that is less, batch output will turn ON.
6. After batch output turns ON, the ON state will be held even if the batch count set value is changed to a value greater than the batch count
value.
C-116
Multifunction Preset Counter
H7CX (Counter Function)
• The total counter continues to count the
total accumulated value when the present
value is reset using reset/reset 1 input
(reset key).
• The total count value is reset when the
total reset/reset 2 input is turned ON. If the
reset key is pressed while the total count
value is displayed, the total count value is
reset. The present value is also reset at
this time.
• The counting range of the total counter is
−99,999 to 999,999 (−999 to 9,999). The
total count value returns to 0 when it
reaches the full scale limit.
• The batch counter continues after count
completion.
• Batch output is held until batch counter
reset is input.
• When the batch counter reset input is
turned ON, the batch count value is reset,
and batch output turns OFF.
• If the reset key is pressed while the batch
count value is displayed, the batch count
value is reset and batch output turns OFF.
The present value is also reset at this time.